Skip to product information
1 of 3

YNT512D-Q12

Brand: Yokogawa
Order Number: YNT512D-Q12
Type: V Net Bus Repeater Module
Country:
Low stock: 15 left

Description

Caret Down

The Yokogawa YNT512D-Q12 is identified in supplier product listings as a V Net Bus Repeater Module for Yokogawa control network applications. Its function is to regenerate and retransmit network signals between connected bus segments. The repeater supports communication infrastructure rather than direct process signal acquisition or control output.

Functional Description

A bus repeater operates at the communication level. It receives signals from one network segment and retransmits them to another, helping maintain signal quality across the network.

The YNT512D product family is referenced in Yokogawa documentation for V Net repeater configurations. The documented system configuration includes transceiver control units, electrical transceiver units, power supply units, and V Net connector units.

V Net Network Configuration

Yokogawa documentation identifies the YNT512D-Q configuration as a dual-redundant V Net bus repeater designed to convert between 10BASE-2 and 10BASE-5 cable segments.

This configuration allows different V Net cable types to be connected within the same network. The repeater is used to extend communication distance while maintaining the specified bus topology and termination requirements.

Transmission Distance

The documented transmission limits depend on the cable type and number of repeaters:

Parameter Specification
10BASE-2 segment Maximum 185 m per repeater extension
10BASE-5 segment Maximum 500 m per repeater extension
Maximum repeaters 8 between any two stations
YNT512D-Q configuration Maximum 500 m cable segment
Total distance with 1 repeater Maximum 0.685 km
Total distance with 2 repeaters Maximum 0.870 km
Total distance with 3 repeaters Maximum 1.370 km
Total distance with 4 repeaters Maximum 1.555 km

These values are specified for the YNT512D-Q configuration in Yokogawa's communication device manual. They should not be interpreted as unrestricted cable lengths independent of network topology.

Technical Specifications

Parameter Specification
Model YNT512D-Q12
Brand Yokogawa
Product Type V Net Bus Repeater Module
Network Yokogawa V Net
Network Configuration Dual-redundant
Cable Conversion 10BASE-2 to 10BASE-5
Transceiver Type Electrical transceiver
Controller Unit AIP171 (documented YNT512D-Q configuration)
Transceiver Unit AIP571 (documented YNT512D-Q configuration)
Power Supply Options PW501, PW502, PW504 (documented assembly options)

Frequently Asked Questions

Q: What is the difference between YNT512D-P, YNT512D-V, and YNT512D-Q?

A: Yokogawa documentation distinguishes these configurations by cable type. YNT512D-P is for dual-redundant 10BASE-2, YNT512D-V is for dual-redundant 10BASE-5, and YNT512D-Q supports conversion between 10BASE-2 and 10BASE-5.

Q: Can YNT512D-Q extend the V Net communication distance?

A: Yes. The repeater extends the V Net transmission distance. The documented maximum segment distances are 185 m for 10BASE-2 and 500 m for 10BASE-5, subject to the specified network configuration.

Q: Which power supply units are used in the YNT512D-Q assembly?

A: The documented assembly uses two power supply units. The listed options are PW501 for 100-120 V AC, PW502 for 220-240 V AC, and PW504 for 24 V DC. The correct configuration depends on the installed power supply arrangement.


Product Benefits

Caret Down

Reviews

Caret Down

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details