Skip to product information
1 of 3

SDV144-S13/D4A00 S2

Brand: Yokogawa
Order Number: SDV144-S13/D4A00 S2
Type: Digital Input Module
Country:
Low stock: 15 left

Description

Caret Down

The Yokogawa SDV144-S13/D4A00 S2 is a 16-channel digital input module designed to receive contact status signals from field devices and transfer their states to a control system. It supports 24 V DC no-voltage contact inputs and provides module-level isolation between the field input circuits and the system. The SDV144 platform is used for digital status acquisition in Yokogawa control and safety-related automation configurations.

Input Function and Signal Processing

The SDV144 receives discrete signals from external dry contacts, such as relay contacts and field status switches. Each input channel detects the contact state and converts it into digital information for the control system.

The module uses a 24 V DC sensing circuit. Its input resistance thresholds distinguish closed and open contact conditions, while the module isolation separates the field-side input circuits from the system side. This arrangement supports the acquisition of multiple independent equipment status signals.

Technical Specifications

Parameter Specification
Model SDV144-S13/D4A00 S2
Brand Yokogawa
Product Type Digital Input Module
Input Channels 16
Input Signal No-voltage contact (dry contact)
Nominal Input Voltage 24 V DC
Input Current 6 mA +/- 20% at 24 V DC, 0 ohm input
ON Resistance 1 k ohm maximum
OFF Resistance 100 k ohm minimum
Maximum Instantaneous Input Voltage 30 V DC
Input Response Time 40 ms maximum
External Power Supply 24 V DC
External Supply Current Capacity 200 mA
Current Consumption 5 V DC: 290 mA maximum
Current Consumption 24 V DC: 140 mA maximum
Isolation Module isolation
Withstand Voltage 2 kV AC, input signal to system

Input Signal Requirements

The SDV144 is intended for voltage-free contact signals rather than direct measurement of externally powered voltage signals. The specified ON and OFF resistance thresholds define the electrical conditions used to recognize contact closure and opening.

The external 24 V DC supply provides the input sensing circuit with its required operating power. The 30 V DC instantaneous input limit should be observed when checking field wiring and external signal conditions.

Frequently Asked Questions

Q: Can the SDV144-S13 be connected directly to dry-contact field devices?

A: Yes. The module is designed for no-voltage contact inputs. Field contacts must meet the specified input resistance and contact electrical requirements.

Q: How many digital input signals can one module handle?

A: The SDV144 provides 16 input channels. Each channel is used to acquire a discrete contact state for system monitoring or control logic.

Q: Is the SDV144 a digital output module?

A: No. It is a digital input module. It receives external contact signals and reports their states to the control system; it does not provide switched output power to field loads.

Contact Isolation and System Integration

The SDV144 supports dual-redundant configuration in compatible Yokogawa system architectures. This allows contact status acquisition to be configured with redundant modules where the application design requires it. Redundancy is a system configuration feature and should not be interpreted as an automatic property of a single module.

The specified withstand voltage is 2 kV AC for one minute between the input signal and system, with all 16 input lines connected collectively. This rating applies under the manufacturer's stated test conditions. Yokogawa recommends a floating field power supply for higher noise immunity.

Field Wiring and Diagnostics

For applications requiring field wiring fault detection, Yokogawa specifies optional SCB100 and SCB110 diagnostic elements:

  • SCB100: Supports open-circuit detection when the normal input state is OFF.
  • SCB110: Supports short-circuit detection when the normal input state is ON.
  • Both elements can be used together when both open- and short-circuit detection are required.

These components are additional field wiring elements, not built-in diagnostic functions that should be assumed to be present in every SDV144 installation.

Product Identification and Ordering

The SDV144-S13 is documented as a 16-channel digital input module with ISA Standard G3 compatibility and a specified operating temperature range of -20 to 70 deg C. The manufacturer identifies pressure-clamp terminal, MIL cable and dedicated signal cable connection arrangements for this module family.

The complete ordering reference supplied for this product is SDV144-S13/D4A00 S2. The /D4A00 option and S2 designation should be retained when checking replacement stock and nameplate identification.


Product Benefits

Caret Down

Reviews

Caret Down

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details

Recommended products