Skip to product information
1 of 3

NFTP5S-00

Brand: Yokogawa
Order Number: NFTP5S-00
Type: Pressure Clamp Terminal Block
Country:
Low stock: 15 left

Description

Caret Down

The Yokogawa NFTP5S-00, also identified as the NFTP5S-00 Pressure Clamp Terminal Block, is a field wiring interface component designed to connect external field conductors with industrial I/O circuits. Its pressure-clamp connection arrangement provides mechanical conductor retention and electrical contact for control signal wiring. The terminal block is identified in third-party product listings as a Yokogawa pressure clamp terminal assembly.

Hardware Specifications

Parameter Specification
Model NFTP5S-00
Brand Yokogawa
Product Type Pressure Clamp Terminal Block
Weight 0.5 kg
Dimensions 185 x 100 x 40 mm
Operating Temp -20 to 60 deg C
Connection Method Pressure clamp terminals
Primary Function Field wiring termination

Field Wiring Interface and Signal Integrity

The NFTP5S-00 provides a mechanical and electrical termination point between field conductors and the associated control-system wiring interface.

The pressure-clamp arrangement retains conductors through contact pressure rather than relying solely on conventional screw-terminal fastening. Correct conductor preparation and insertion are necessary to maintain contact quality.

For DCS and process-control installations, channel assignment, conductor polarity, terminal identification, and the associated I/O module wiring diagram must be checked before commissioning.

Channel-to-channel isolation and surge protection characteristics should not be assumed without the applicable Yokogawa hardware documentation.

Frequently Asked Questions (FAQ)

Q: Can the NFTP5S-00 be replaced while the control system is energized?

A: Hot-swap capability has not been verified. Isolate the associated circuits and follow the system maintenance procedure before removing or replacing the terminal block.

Q: Does the NFTP5S-00 require an independent power supply?

A: No independent power consumption specification has been verified. Its electrical requirements should be checked against the associated I/O hardware documentation.

Q: Can this terminal block be used with any Yokogawa I/O module?

A: Compatibility should not be assumed across Yokogawa product families. Confirm the terminal block part number against the applicable I/O module and system hardware configuration.

Field Installation Guidelines

1. Mechanical Mounting: Check the terminal block mounting arrangement and ensure that the assembly is secured to the designated panel or mounting structure.

2. Conductor Preparation: Prepare field conductors according to the applicable terminal specifications. Avoid damaged insulation, exposed excess conductor, and loose wire strands.

3. Signal Wiring: Verify terminal numbering, signal polarity, and field-device identification against the approved wiring diagram.

4. Cable Routing: Separate low-level instrumentation signals from power cables and high-current switching conductors to reduce electromagnetic interference.

5. Shield Grounding: Terminate cable shields according to the system grounding design. Avoid creating unintended ground loops.

6. Commissioning: Inspect conductor retention, terminal identification, and wiring continuity before energizing the associated I/O circuits.