NFAF135-S00
Description
Description
The Yokogawa NFAF135-S00 is an 8-channel frequency input module for the STARDOM FCN control platform. It measures pulse signals from contact inputs and voltage pulse sources, converting pulse intervals into frequency values for controller processing. Its individually isolated input channels support frequency measurement from 0.1 Hz to 10 kHz, with a specified accuracy of 0.1% of reading.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | NFAF135-S00 |
| Brand | Yokogawa |
| Product Type | Frequency Input Module |
| Number of Input Channels | 8 |
| Channel Isolation | Individually isolated channels |
| Input Signal | Contact ON/OFF, voltage pulse (rectangular wave) |
| Input Frequency Range | 0.1 Hz to 10 kHz |
| Frequency Accuracy | 0.1% of reading |
| Minimum Input Pulse Width | 40 us |
| Withstanding Voltage | 500 V AC for 1 minute, input-to-system and channel-to-channel |
| Contact Input Open Level | 100 kOhm or more |
| Contact Input Close Level | 200 Ohm or less |
| Voltage Pulse High Level (VH) | 3 to 24 V DC |
| Voltage Pulse Low Level (VL) | -1 to 8 V DC |
| Voltage Pulse Swing (VH-VL) | 3 V or more |
| Voltage Pulse Source Resistance | 1 kOhm or less |
| Shunt Resistance | Selectable: OFF or 1000 Ohm |
| Pull-up Resistance | 68 kOhm |
| Data Refresh Cycle | 10 ms |
Frequency Measurement and Signal Processing
The NFAF135-S00 measures the time intervals between incoming pulses and calculates the corresponding frequency. The controller can use these frequency values to monitor rotational speed and other pulse-based process variables.
The module uses pulse-edge detection and interval measurement to calculate frequency. Its measurement method accumulates pulse counts and their time intervals to reduce the influence of clock resolution, particularly when measuring higher-frequency signals. At lower frequencies, the measurement update period can extend beyond the normal 10 ms cycle to accommodate longer pulse intervals.
Field Signal Requirements and Power Supply
The module accepts three basic signal configurations: open-collector contact pulses, relay contact pulses, and rectangular voltage pulses. The input connection and shunt resistance settings must match the selected signal type.
For contact inputs, the electrical capacity of the contact must meet the specified excitation requirements. Voltage pulse sources must provide a swing of at least 3 V, with a signal source resistance no greater than 1 kOhm.
The field power supply can be selected between 12 V DC and 24 V DC. The respective current limiter values are 40 mA and 30 mA. The FCN power supply module must receive 24 V DC at its analog field power supply terminal when the NFAF135 is installed.
Electrical and Mechanical Characteristics
The module has a maximum current consumption of 300 mA at 5 V DC and 400 mA at 24 V DC. Its weight is 0.3 kg. External field connections are available through pressure-clamp terminals or a MIL connector cable, depending on the selected connection configuration.
The specified 500 V AC withstand voltage applies between input and system and between individual input channels. When using a MIL connector cable, the actual withstand voltage also depends on the cable's electrical specifications.
Model Identification
The NFAF135 product family is documented as a frequency input module with eight individually isolated channels. The supplied model reference is NFAF135-S00. The available manufacturer documentation describes the NFAF135 suffix and option coding, but does not establish a complete code-by-code interpretation of the exact -S00 designation. The full ordering configuration should therefore be checked against the product nameplate or original ordering record.
Frequently Asked Questions
Q: Can the NFAF135-S00 accept both contact and voltage pulse signals?
A: Yes. It supports open-collector contact pulses, relay contact pulses, and rectangular voltage pulses. The terminal connections and shunt resistance settings must be selected according to the input mode.
Q: Can all eight channels measure frequencies up to 10 kHz?
A: The specified frequency range is 0.1 Hz to 10 kHz. However, open-collector dry-contact input has additional limitations: its maximum frequency is 800 Hz under the specified 1000 pF connection-capacity condition. Higher wiring and equipment capacitance further reduces the permitted frequency.
Q: What power supply is required for field signal excitation?
A: The module provides selectable 12 V DC or 24 V DC field power. The current limiter values are 40 mA and 30 mA, respectively. The FCN power supply module must also supply 24 V DC to its analog field power supply terminal.
Product Benefits
Product Benefits
- 100% genuine products in stock with fast delivery. Learn more...
- 30-day return policy for quality assurance. Learn more...
- 12-month warranty for peace of mind. Learn more...
Reviews
Reviews

Have a question?
Notified by email when this product becomes available
Recommended products
Recently viewed product
Subscribeto our emails
Be the first to know about new collections and exclusive offers.