Skip to product information
1 of 3

TM3AM6

Brand: Schneider
Order Number: TM3AM6
Type: Modicon TM3 Analog I/O Module
Country:
Low stock: 17 left

Description

Caret Down

Configured for analog signal acquisition and output in Modicon M2xx and M262 controller systems, the Schneider Electric TM3AM6 (TM3AM6 analog I/O module) provides four analog inputs and two analog outputs with 12-bit or 11-bit plus sign resolution and 24 VDC supply.

Hardware Specifications

Parameter Specification
Model TM3AM6
Brand Schneider Electric
Product Type Modicon TM3 analog I/O module
Origin Japan
Range Modicon TM3
Compatible Controllers Modicon M221, M241, M251, M262
Analog Inputs 4
Analog Outputs 2
Input Signals 4-20 mA, 0-20 mA, 0-10 V, -10 to 10 V
Output Signals 4-20 mA, 0-20 mA, 0-10 V, -10 to 10 V
Input Resolution 12 bits or 11 bits + sign
Supply Voltage 24 VDC
Bus Current Consumption 45 mA at 5 VDC no load; 55 mA at 5 VDC full load
External Supply Consumption 55 mA at 24 VDC no load; 100 mA at 24 VDC full load
Input Impedance <= 50 Ohm current; >= 1 MOhm voltage
Sampling Duration 1 ms
Stabilization Time 1 ms
Output Load 1 kOhm voltage; 300 Ohm current
Conversion Time 1 ms + 1 ms per channel + 1 controller cycle time
Absolute Accuracy +/- 1 % FS; +/- 0.2 % FS at 25 deg C
Non-Linearity +/- 0.2 % FS
Repeat Accuracy +/- 0.5 % FS input
Output Ripple 20 mV
Cross Talk <= 1 LSB
Input/Output Cable Twisted shielded pairs, <30 m
Isolation Input/supply 1500 VAC; input/internal logic 500 VAC; output/supply 1500 VAC; output/internal logic 500 VAC
Mounting TH35-15 or TH35-7.5 IEC 60715 DIN rail; plate/panel with fixing kit
Dimensions 23.6 W x 70 D x 90 H mm
Weight 0.11 kg
Operating Temp -10 to 55 deg C horizontal; -10 to 35 deg C vertical
Storage Temp -25 to 70 deg C
Relative Humidity 10-95 % without condensation
Protection Rating IP20
Operating Altitude 0-2000 m
Power Indicator Green PWR LED
Standards IEC 61131-2
Certifications CE, UKCA, RCM, EAC, cULus, cULus HazLoc

Analog Signal Interface and PLC Bus Characteristics

The TM3AM6 converts voltage and current signals between field devices and the Modicon controller through the TM3 expansion bus. Each analog input supports 4-20 mA, 0-20 mA, 0-10 V, or -10 to 10 V operation. Analog outputs provide the same four signal ranges for devices such as variable speed drives or other voltage/current-controlled equipment.

The module uses a removable terminal connection and a bus expansion connector for data and supply distribution within the TM3 assembly. Input and output circuits have separate isolation paths from the supply and internal logic. Cross talk is specified at <= 1 LSB, while the stated temperature drift is +/- 0.01 % FS/deg C.

Frequently Asked Questions

Q: What controller platforms are compatible with the TM3AM6?
A: The module is compatible with Modicon M221, M241, M251, and M262 logic controllers.

Q: What analog signal ranges can the module process?
A: Inputs and outputs support 4-20 mA, 0-20 mA, 0-10 V, and -10 to 10 V. Input resolution is 12 bits or 11 bits + sign.

Q: What are the physical mounting options?
A: The module can be mounted on TH35-15 or TH35-7.5 DIN rail conforming to IEC 60715, or on a plate/panel using the specified fixing kit.

Field Installation Guidelines

  • Install the module on the specified DIN rail or panel mounting surface and engage the TM3 interlocking mechanism before connecting the expansion bus.
  • Use twisted shielded pairs for analog field wiring. Keep analog cables separated from high-current power and switching conductors where practical.
  • Connect cable shields according to the plant grounding scheme and avoid creating unintended ground loops.
  • Verify whether each field circuit is configured for current or voltage operation before wiring the removable terminals.
  • Observe the stated input overload limits and output load impedance when connecting external devices.
  • Confirm the required isolation between field circuits, the 24 VDC supply, and internal controller logic.
  • Maintain the specified environmental limits for temperature, humidity, altitude, vibration, and shock.
  • Check the PWR LED after energization and verify the controller recognizes the TM3 expansion module before commissioning analog channels.

Product Benefits

Caret Down

Reviews

Caret Down

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details

Recommended products