TM241CE40T
Description
Description
Configured for compact machine control with discrete I/O, high-speed counting, positioning, and Ethernet communication in the Modicon M241 platform, the Schneider Electric TM241CE40T (M241 Logic Controller) provides 40 integrated I/O points with 24 VDC transistor outputs and multiple communication interfaces.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | TM241CE40T |
| Brand | Schneider Electric |
| Series | Modicon M241 |
| Product Type | Logic Controller |
| Origin | Indonesia |
| Rated Supply Voltage | 24 VDC |
| Supply Voltage Limits | 20.4-28.8 VDC |
| Discrete I/O | 40 |
| Discrete Inputs | 24, including 8 fast inputs |
| Discrete Outputs | 16 transistor outputs, including 4 fast outputs |
| Output Logic | Positive logic, source |
| Transistor Output Current | 0.5 A per output |
| Fast Output Current | 0.1 A |
| Maximum Output Frequency | 20 kHz PWM, 100 kHz PLS, 1 kHz standard output |
| Fast Input Frequency | Up to 200 kHz HSC |
| Positioning Outputs | 4 PTO outputs, up to 100 kHz |
| Program Memory | 8 MB |
| System Memory RAM | 64 MB |
| Built-in Flash | 128 MB |
| Optional SD Card | Up to 16 GB |
| Ethernet | 10BASE-T/100BASE-TX, RJ45 |
| Ethernet Protocols | Modbus TCP, EtherNet/IP, OPC UA, FTP, SNMP and web services |
| Serial Interface 1 | RJ45, RS232/RS485, non-isolated |
| Serial Interface 2 | Removable terminal block, RS485, non-isolated |
| USB | Mini B USB 2.0 |
| Ethernet Transmission Rate | 10/100 Mbit/s |
| Serial Transmission Rate | 1.2-115.2 kbit/s |
| Power Consumption | 32.6-40.4 W with maximum I/O expansion |
| Dimensions | 190 x 95 x 90 mm (W x D x H) |
| Weight | 0.62 kg |
| Operating Temperature | -10 to 50 deg C vertical; -10 to 55 deg C horizontal |
| Storage Temperature | -25 to 70 deg C |
| Protection Rating | IP20 with protective cover |
| Mounting | TH35-15 rail, TH35-7.5 rail, plate or panel |
| Maximum Local I/O Expansion | 7 modules |
| Maximum Remote I/O Expansion | 14 modules |
| Output Common Current | 2 A maximum |
| Input Response Time | 50 us standard; <= 2 us fast inputs |
| Output Response Time | <= 34 us turn-on; <= 250 us turn-off standard outputs |
| Insulation | 500 VAC between specified supply, logic, input and output circuits |
| Surge Withstand | Up to 1 kV common-mode and 0.5 kV differential-mode values depending on circuit |
| Certifications | CE, cULus, RCM, UKCA, DNV-GL, ABS, LR |
Ethernet, I/O Density and Firmware Functions
The TM241CE40T combines 40 integrated discrete I/O points with Ethernet and serial communication interfaces. The 24 inputs include 8 fast inputs supporting high-speed counting functions up to 200 kHz. Four transistor outputs provide fast output functions, with PWM operation up to 20 kHz and PLS operation up to 100 kHz.
The Ethernet interface operates at 10/100 Mbit/s and supports Modbus TCP client/server functions and EtherNet/IP scanner and target functions. The controller also provides firmware updating through its Ethernet service set. Application memory consists of 8 MB program memory, 64 MB system RAM, and 128 MB built-in flash for user-program backup.
The controller supports EcoStruxure Machine Expert for application programming. Its integrated Ethernet services include DHCP, SNMP, FTP, web server, OPC UA server, SQL client, and Modbus TCP and EtherNet/IP communication functions.
Frequently Asked Questions
Q: What supply voltage does the TM241CE40T require?
A: The controller is rated for 24 VDC, with a specified supply range of 20.4-28.8 VDC.
Q: Are the integrated Ethernet and serial interfaces electrically isolated?
A: The Ethernet interface is provided through an RJ45 connection. Both integrated serial links are specified as non-isolated.
Q: What are the fast I/O limits?
A: Eight fast inputs support HSC operation up to 200 kHz. Four fast transistor outputs support PWM up to 20 kHz and PLS up to 100 kHz.
Field Installation Guidelines
- Mount the controller on a TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or use the specified plate or panel mounting method.
- Supply the controller within the specified 20.4-28.8 VDC range and observe the 50 A stated inrush current when sizing the power supply and protective devices.
- Use the removable screw terminal blocks for 24 VDC power and discrete I/O connections. The specified terminal pitch is 5.08 mm.
- Keep input and output wiring within the specified cable-distance limits. Standard input and output wiring is specified up to 50 m with unshielded cable.
- For fast signals, observe the shorter specified limits: shielded fast-input wiring is limited to 10 m and shielded fast-output wiring to 3 m.
- Route fast I/O and communication cables separately from high-current or high-noise conductors where practical to reduce electrical interference.
- Connect cable shields according to the machine grounding design and applicable EMC requirements. Avoid creating unintended ground loops through multiple shield termination paths.
- Maintain the specified environmental limits of -10 to 50 deg C for vertical installation or -10 to 55 deg C for horizontal installation, with non-condensing humidity.
- Keep the controller within its IP20 installation environment and use the protective cover where specified.
- For Ethernet commissioning, verify the assigned IP configuration and communication parameters before enabling Modbus TCP or EtherNet/IP data exchange.
- When using high-speed inputs or outputs, verify signal wiring, polarity, load characteristics, and configured frequency before applying the machine power stage.
Product Benefits
Product Benefits
- 100% genuine products in stock with fast delivery. Learn more...
- 30-day return policy for quality assurance. Learn more...
- 12-month warranty for peace of mind. Learn more...
Reviews
Reviews

Have a question?
Notified by email when this product becomes available
Recommended products
Recently viewed product
Subscribeto our emails
Be the first to know about new collections and exclusive offers.