Skip to product information
1 of 2

STBXSP3010

Brand: Schneider
Order Number: STBXSP3010
Type: Modicon STB Grounding Kit Terminal
Country:
Low stock: 17 left

Description

Caret Down

Configured for shielded cable grounding connection in the Modicon STB distributed I/O solution, the Schneider Electric STBXSP3010 (STBXSP3010 terminal for grounding kit) provides direct physical grounding termination for shielded cables with 1.5 to 6 mm2 cross-section.

Hardware Specifications

Parameter Specification
Model STBXSP3010
Brand Schneider Electric
Product Type Grounding Kit Terminal
Range Modicon STB distributed I/O solution
Accessory Type Protection accessory terminal
Application Terminal for grounding kit
Cable Compatibility Shielded cable, 1.5 to 6 mm2 cross-section
Quantity per Set Set of 10
Origin CH
Weight 139 g 
Dimensions 22.5 x 16.5 x 1 cm
Power Consumption Passive grounding accessory, no power consumption

Industrial Control Grounding and Shield Termination

The STBXSP3010 is a Modicon STB accessory component designed for the physical termination of shielded cable grounding connections. It provides a dedicated mechanical connection point between cable shielding and the grounding kit assembly, supporting noise control practices in distributed I/O installations.

The terminal accepts shielded cables within the specified 1.5 to 6 mm2 cross-section range. Proper shield bonding maintains the intended electrical reference between field wiring shields and the protective grounding structure of the STB installation.

For Schneider Electric Modicon STB systems, grounding accessories are installed together with I/O island wiring components to maintain cable shield continuity and reduce unwanted electrical interference coupling into signal circuits.

Frequently Asked Questions

Q: What cable size range is compatible with the STBXSP3010 terminal?
A: The STBXSP3010 is specified for shielded cables with a cross-section range of 1.5 to 6 mm2.

Q: Does the STBXSP3010 require an external power supply?
A: No. The STBXSP3010 is a passive grounding terminal accessory and does not consume electrical power.

Q: What installation consideration applies when connecting the grounding terminal?
A: The cable shield should maintain continuous contact with the grounding path, and grounding conductors should be routed separately from high-noise power wiring where applicable.

Field Installation Guidelines

Install the STBXSP3010 terminal according to the Modicon STB island grounding arrangement and the applicable system installation documentation.

Ensure the shielded cable jacket is prepared to provide direct shield contact with the grounding terminal. Avoid excessive bending or mechanical stress at the cable entry point. Keep shield termination paths short and maintain separation between signal wiring and high-current conductors.

Verify that grounding connections are mechanically secured and that the protective grounding network has proper continuity before commissioning the I/O system.