PC-E984-485
Description
Description
Configured for logic execution and Modbus communication control in the Modicon 984 automation platform, the Schneider Electric PC-E984-485 (PC-E984-485 Programmable Controller) provides direct physical/electrical execution. The controller integrates 16K-word user RAM, 2K-word data storage, discrete I/O management, and Modbus RTU/Modbus Plus communication interfaces for industrial control processing.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | PC-E984-485 |
| Brand | Schneider Electric |
| Product Line | Modicon 984 |
| Product Type | Programmable Controller |
| Weight | 1.39 kg |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | Not specified |
| Power Supply | 115/230 VAC, 50/60 Hz |
| User Memory (RAM) | 16K words |
| Data Memory | 2K words |
| Logic Solve Time | 3 milliseconds per kiloword |
| State RAM Registers | 1920 |
| Discrete Inputs/Outputs | 2048 points |
| Maximum I/O Bits per Drop | 512 inputs / 512 outputs |
| Maximum Drops per System | 6 |
| Expansion Modules | Up to 2 remote racks |
| Communication Ports | 1 Modbus RTU port, 1 Modbus Plus port |
| Relative Humidity | 5 to 95 % without condensation |
| Storage Temperature | -25 deg C to 70 deg C |
Modicon 984 Backplane and Communication Architecture
The PC-E984-485 operates within the Modicon 984 controller architecture with dedicated memory allocation for application logic, data registers, and state RAM operations. The controller supports distributed I/O configurations through remote rack expansion and manages up to 2048 discrete input/output points.
The integrated Modbus RTU and Modbus Plus communication ports provide serial data exchange with connected field devices and Modicon network components. System configuration depends on the selected I/O architecture, rack arrangement, and communication requirements.
Frequently Asked Questions
Q: What communication interfaces are integrated in the PC-E984-485?
A: The controller includes one Modbus RTU port and one Modbus Plus port for serial communication with compatible devices and Modicon network components.
Q: How is I/O capacity handled by the PC-E984-485 controller?
A: The controller supports up to 2048 discrete inputs/outputs, with each drop supporting up to 512 inputs and 512 outputs.
Q: Can the PC-E984-485 support remote I/O expansion?
A: The controller supports expansion through up to two remote racks within the Modicon 984 system configuration.
Field Installation Guidelines
Install the PC-E984-485 in a control cabinet with adequate mechanical support and protection from conductive contaminants. Verify the 115/230 VAC supply wiring before energizing the controller.
Use appropriate grounding practices for the cabinet enclosure and communication cable shields. Separate communication wiring from high-current power conductors to reduce electrical interference. Confirm Modbus RTU and Modbus Plus cable routing, termination, and connector integrity according to the network installation requirements.
Before commissioning, verify rack addressing, I/O allocation, communication parameters, and application memory configuration within the Modicon 984 system.
Product Benefits
Product Benefits
- 100% genuine products in stock with fast delivery. Learn more...
- 30-day return policy for quality assurance. Learn more...
- 12-month warranty for peace of mind. Learn more...
Reviews
Reviews

Have a question?
Notified by email when this product becomes available
Recommended products
Recently viewed product
Subscribeto our emails
Be the first to know about new collections and exclusive offers.