PM5100
Description
Description
Configured for electrical energy measurement and power quality monitoring in PowerLogic PM5000 platforms, the Schneider Electric METSEPM5100 (PM5100 Power Meter) provides direct measurement of voltage, current, frequency, power factor, active/reactive power, energy values, and harmonic components up to the 15th order.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | METSEPM5100 |
| Brand | Schneider Electric |
| Product Series | PowerLogic PM5000 |
| Product Type | Power Meter |
| Weight | 380 g |
| Dimensions | 96 mm W x 72 mm D x 96 mm H |
| Operating Temp | -25 to 70 deg C (meter); -20 to 70 deg C (display) |
| Power Consumption | 11 VA maximum at 415 VAC |
| Display Type | Monochrome graphic LCD, 128 x 128 pixels |
| Mounting Mode | Flush-mounted |
| Rated Supply Voltage | 90 to 450 VAC, 45 to 65 Hz; 100 to 300 VDC |
| Rated Current Input | 1 A or 5 A |
| Network Configuration | 1P + N, 3P, 3P + N |
| Measurement Voltage | 35 to 760 VAC between phases; 20 to 400 VAC between phase and neutral |
| Frequency Range | 45 to 65 Hz |
| Sampling Rate | 64 samples/cycle |
| Harmonic Measurement | Up to 15th harmonic |
| Accuracy Class | Class 0.5S active energy according to IEC 62053-22 |
| Pulse Output | 1 energy pulse output |
| Alarm Function | 33 configurable alarms |
| Protection Rating | IP54 front display, IP30 rear enclosure |
| Certifications | CE, cULus |
Deterministic Network and Power Measurement Characteristics
The METSEPM5100 integrates electrical acquisition circuits for three-phase and single-phase power monitoring. The measurement engine processes voltage and current input signals with 64 samples per cycle and calculates active power, reactive power, apparent power, energy, frequency, and power factor values.
The meter supports power quality analysis through harmonic measurement up to the 15th harmonic component. Measurement accuracy is defined by IEC 62053-22 Class 0.5S requirements for active energy.
The device includes a pulse output channel for remote energy accumulation and provides configurable alarm handling with 33 alarm conditions. Recorded data includes minimum and maximum instantaneous values with time stamping functions.
Frequently Asked Questions
Q: What current input signals are supported by the METSEPM5100?
A: The meter accepts line current inputs rated at 1 A or 5 A for current transformer measurement circuits.
Q: Does the METSEPM5100 provide serial communication ports?
A: The METSEPM5100 model provides pulse output communication only. No communication protocol is assigned for the communication port.
Q: What mounting method is required for installation?
A: The meter is installed using a flush-mounted configuration with a framework mounting support.
Field Installation Guidelines
Install the METSEPM5100 in a panel cutout suitable for the 96 mm x 96 mm front display format. Connect voltage sensing circuits, current transformer inputs, and pulse output wiring according to the terminal assignment documentation.
Current transformer secondary wiring should maintain correct polarity and avoid open-circuit operation during commissioning. Separate measurement wiring from high-voltage switching conductors where possible to reduce electrical interference.
Protect signal wiring with proper grounding and shielding practices according to the installation environment. Verify phase sequence, network configuration, and rated input settings before energizing the meter.
Product Benefits
Product Benefits
- 100% genuine products in stock with fast delivery. Learn more...
- 30-day return policy for quality assurance. Learn more...
- 12-month warranty for peace of mind. Learn more...
Reviews
Reviews

Have a question?
Notified by email when this product becomes available
Recommended products
Recently viewed product
Subscribeto our emails
Be the first to know about new collections and exclusive offers.