ATV930C22N4

Brand: Schneider
Order Number: ATV930C22N4
Type: Altivar Process ATV900 Variable Speed Drive
Country:
Low stock: 17 left

Description

Caret Down

Configured for 3-phase motor speed control in the Altivar Process ATV900 platform, the Schneider Electric ATV930C22N4 (ATV930 variable speed drive) provides direct electrical control for synchronous and asynchronous motors. The unit is rated for 380 to 480 VAC input, 220 kW normal-duty motor power, and includes an integrated braking chopper.

Hardware Specifications

Parameter Specification
Model ATV930C22N4
Base Model ATV930
Brand Schneider Electric
Product Type Variable Speed Drive
Series Altivar Process ATV900
Variant Standard version with braking chopper
Motor Type Asynchronous and synchronous motors
Phase 3 phase
Rated Supply Voltage 380 to 480 VAC, -15% to +10%
Motor Power 220 kW normal duty; 160 kW heavy duty
Continuous Output Current 427 A normal duty; 302 A heavy duty
Maximum Transient Current 512 A for 60 s normal duty; 453 A for 60 s heavy duty
Output Voltage Up to 480 VAC
Maximum Output Frequency 599 Hz
Switching Frequency 1 to 8 kHz adjustable; 2.5 to 8 kHz with derating
Nominal Switching Frequency 2.5 kHz
Braking Chopper Integrated
Input Frequency 50 to 60 Hz
Apparent Power 247 kVA at 480 V normal duty; 187 kVA at 480 V heavy duty
Communication Modbus serial, Modbus TCP, EtherNet/IP
Ethernet Rate 10/100 Mbit/s
Modbus Serial Rate 4.8, 9.6, 19.2, 38.4 kbit/s
Physical Interfaces Ethernet, 2-wire RS-485
Ethernet Connectors 2 x RJ45
Modbus Connector 1 x RJ45
Digital Inputs 10; DI1 to DI8 programmable, DI7/DI8 pulse input, STOA/STOB
Analog Inputs 3; 0 to 10 VDC or 0 to 20 mA / 4 to 20 mA, 12 bit
Analog Outputs 2; 0 to 10 VDC or 0 to 20 mA, 10 bit
Relay Outputs 3 configurable relay outputs
Safe Torque Off Yes
Safe Stop 1 Yes
Safely Limited Speed Yes
Safe Brake Management Yes
IP Rating IP00
Mounting Wall mount, vertical +/- 10 deg
Width 440 mm
Height 1195 mm
Depth 380 mm
Weight 172 kg
Operating Temp -10 to 40 deg C without derating; 40 to 60 deg C with derating
Storage Temp -25 to 70 deg C
Relative Humidity 5 to 95% without condensation
Operating Altitude Up to 1000 m without derating; 1000 to 3000 m with current derating
Power Dissipation 5030 W forced convection at 380 V, 2.5 kHz; 451 W natural convection at 380 V, 2.5 kHz
Cooling Air Volume 860 m3/h
Prospective Line Isc 50 kA
Insulation Resistance >1 MOhm at 500 VDC for 1 minute to earth
Certifications CSA, TÜV, UL
Standards UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 61508, IEC 13849-1
Origin IN

Industrial Control and Drive Communication

The ATV930C22N4 exchanges control and diagnostic data through Modbus serial, Modbus TCP, and EtherNet/IP interfaces. Ethernet communication operates at 10/100 Mbit/s with half-duplex, full-duplex, and auto-negotiation modes. The serial Modbus interface uses RS-485 physical signaling with RTU framing and configurable odd, even, or no parity.

The drive provides 10 programmable discrete inputs, three analog inputs, two analog outputs, and three relay outputs. DI7 and DI8 can operate as pulse inputs up to 30 kHz. Analog inputs accept 0 to 10 VDC or 0 to 20 mA / 4 to 20 mA signals. Optional communication and I/O modules support additional network and signal interfaces.

Motor control profiles include constant torque, variable torque, and optimized torque modes for asynchronous motors, plus permanent magnet and synchronous reluctance motor control. The drive supports 4-quadrant operation, adjustable acceleration and deceleration ramps from 0.01 to 9999 s, and a maximum output frequency of 599 Hz.

Frequently Asked Questions

Q: Does the ATV930C22N4 include a braking chopper?

A: Yes. The ATV930C22N4 has an integrated brake chopper for connection to the applicable braking circuit.

Q: What motor feedback and control signals are available?

A: The drive provides three analog inputs, two analog outputs, ten discrete inputs, two discrete outputs, and three configurable relay outputs. Encoder interface modules can be installed through the available option slots.

Q: What safety functions are provided by this model?

A: The documented safety functions include Safe Torque Off (STO), Safe Stop 1 (SS1), Safely Limited Speed (SLS), and Safe Brake Management (SBC/SBT).

Field Installation Guidelines

Mount the drive vertically within the specified +/- 10 deg position range. The enclosure is rated IP00, so installation requires an appropriate protective enclosure or cabinet providing the required environmental and personnel protection.

Route line-side power conductors, motor conductors, control wiring, and communication cables according to the installation manual. Keep low-level analog and communication wiring separated from high-current motor and input power conductors.

Connect protective earth before energizing the power circuit. Maintain the specified conductor cross-sections and terminal arrangements for line, motor, DC bus, and control connections. Shielded signal and communication cables should be terminated according to the applicable EMC installation practice.

Provide the required forced-convection cooling path. The specified cooling air volume is 860 m3/h. Verify cabinet airflow, ambient temperature, altitude, and drive derating requirements before commissioning.

For EtherNet/IP, Modbus TCP, and RS-485 connections, verify cable routing, connector seating, network addressing, and termination requirements before applying control commands. Do not route communication cables in parallel with high-current motor conductors unless the installation method provides the required EMC separation.