AS-B984-100
Description
Description
Configured for discrete high-speed signal handling in the Schneider Electric 800 Series, the Schneider Electric AS-B984-100 (AS-B984-100 Terminal Connector) provides 16 discrete inputs and 8 outputs with 24 VDC operation, defined voltage thresholds, and specified input/output response times.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | AS-B984-100 |
| Brand | Schneider Electric |
| Product Line | 800 Series |
| Product Type | Terminal Connector |
| Weight | 1.69 lbs |
| Mode of Operation | True High |
| Number of Inputs | 16 |
| Number of Outputs | 8 |
| Working Voltage | 20-28 VDC |
| Input Response Time | 100 microsec max, no filtering |
| Output Response Time | 1 msec max |
| ON Level | 19.2 VDC, source impedance < 1 MOhm |
| OFF Level | 6 VDC, source impedance 0 |
| ON Condition Threshold | 18 VDC |
| Input Wetting Current | 6 mA minimum at 24 VDC |
| Source Resistance | 1000 Ohm |
| Minimum Load Current | 100 mA |
| Required Connector | AS-8533-004 |
800 Series Discrete I/O Characteristics
The AS-B984-100 uses a true-high discrete signal scheme for its 16 inputs and 8 outputs. The specified input response time is 100 microsec maximum without filtering, while output response time is 1 msec maximum. Input switching behavior is defined by an 18 VDC ON condition threshold, a 19.2 VDC ON level under the specified source impedance condition, and a 6 VDC OFF level.
The module operates from 20-28 VDC and specifies a minimum 6 mA input wetting current at 24 VDC. The listed source resistance is 1000 Ohm, with a minimum output load current of 100 mA.
Frequently Asked Questions
Q: What supply voltage range is specified for the AS-B984-100?
A: The specified working voltage is 20-28 VDC.
Q: What are the input and output response times?
A: Input response time is 100 microsec maximum without filtering. Output response time is 1 msec maximum.
Q: How many discrete channels are provided?
A: The AS-B984-100 provides 16 inputs and 8 outputs.
Field Installation Guidelines
Install the AS-B984-100 using the designated AS-8533-004 connector. Verify the 20-28 VDC supply range before energizing the circuit. Maintain correct polarity and confirm that connected field devices meet the stated ON and OFF voltage thresholds.
Route discrete signal wiring separately from high-current or high-noise conductors where practical. Apply the control cabinet grounding and shielding practices specified by the system installation documentation. Verify input source impedance and output load requirements against the module specifications before commissioning.
Do not apply operating conditions outside the documented electrical limits. Confirm all terminal assignments and field wiring with the applicable Schneider Electric 800 Series documentation before power-up.
Product Benefits
Product Benefits
- 100% genuine products in stock with fast delivery. Learn more...
- 30-day return policy for quality assurance. Learn more...
- 12-month warranty for peace of mind. Learn more...
Reviews
Reviews

Have a question?
Notified by email when this product becomes available
Recommended products
Recently viewed product
Subscribeto our emails
Be the first to know about new collections and exclusive offers.