IC200MDL940F

Brand: GE Fanuc
Order Number: IC200MDL940F
Type: VersaMax 16-Point Isolated Relay Output Module
Country:
Low stock: 12 left

Description

Caret Down

The GE IC200MDL940F is a 16-point relay output module in the VersaMax I/O product family. It provides individually isolated Form A (normally open) relay contacts for switching external AC and DC loads. Each output operates as an independent dry contact, allowing the PLC to control field devices using separately supplied load power rather than sourcing the load voltage directly from the module.

Technical Specifications

Parameter Specification
Model IC200MDL940F
Base Model IC200MDL940
Brand GE
Product Series VersaMax
Product Type Isolated Relay Output Module
Number of Output Points 16
Output Contact Type Form A, Normally Open (NO)
Relay Mechanism Fixed coil, moving armature
Contact Material Silver alloy
Output Voltage Range (DC) 0-125 VDC
Output Voltage Range (AC) 0-265 VAC, 47-63 Hz
Nominal Output Voltage (DC) 5/24/125 VDC
Nominal Output Voltage (AC) 120/240 VAC
Maximum Load Current 2.0 A per point, 5-265 VAC resistive
Maximum DC Load Current 2.0 A per point, 5-30 VDC resistive; 0.2 A per point, 31-125 VDC
Minimum Load Current 10 mA per point
Output Voltage Drop 0.3 V maximum
ON Response Time 10 ms maximum
OFF Response Time 10 ms maximum
Switching Frequency 20 cycles per minute (inductive load)
Channel Isolation Individually isolated
Group-to-Group Isolation 250 VAC continuous; 1500 VAC for 1 minute
Point-to-Point Isolation 250 VAC continuous; 1500 VAC for 1 minute
Input-to-Logic Isolation 250 VAC continuous
5 V Backplane Current Consumption 490 mA maximum

Relay Output Operation

The IC200MDL940F uses electromechanical relays with normally open Form A contacts. When the PLC commands an output ON, the corresponding relay energizes and closes its contact, completing the external load circuit. When the command is removed, the contact opens.

Because the outputs are individually isolated, each channel can switch its own externally supplied AC or DC circuit. This arrangement separates the PLC backplane logic from the field load supply and allows different output channels to operate independent circuits.

Load Ratings and Switching Limitations

The output current rating depends on the applied voltage and load type. For resistive loads, the contacts support up to 2.0 A per point at 5-265 VAC or 5-30 VDC. For DC loads between 31 and 125 VDC, the maximum current is reduced to 0.2 A per point.

The specified inductive-load switching frequency is 20 cycles per minute. The module has no internal fuses or snubbers, so external circuit protection and appropriate suppression for inductive loads must be considered when designing the field wiring.

Status Indication and Backplane Power

Each output point has an individual green LED indicating its ON/OFF state. An additional OK LED indicates the presence of backplane power. The module draws up to 490 mA from the 5 V backplane supply, which should be included when calculating the power budget of the VersaMax I/O assembly.

Frequently Asked Questions

Q: How many independently isolated outputs does the IC200MDL940F provide?

A: It provides 16 individually isolated Form A normally open relay outputs. Each point can switch an independently supplied AC or DC load within its specified electrical ratings.

Q: Can the IC200MDL940F switch both AC and DC loads?

A: Yes. It supports 0-265 VAC and 0-125 VDC. However, the allowable current depends on the voltage range: DC loads above 30 VDC are limited to 0.2 A per point.

Q: Does the IC200MDL940F include internal output fuses or snubbers?

A: No. The module has no internal fuses or snubbers. External protection and suitable inductive-load suppression should therefore be evaluated as part of the field circuit design.