{"product_id":"schneider-electric-tm3di16-modicon-tm3-discrete-input-module-1","title":"Módulo de entrada discreta Schneider Electric TM3DI16 Modicon TM3","description":"\u003cp\u003eConfigurado para a aquisição de sinais discretos de 24 VCC em sistemas de controladores Modicon M221, M241, M251 e M262, o \u003cstrong\u003eSchneider Electric TM3DI16\u003c\/strong\u003e (\u003cstrong\u003emódulo de entradas discretas TM3DI16\u003c\/strong\u003e) fornece 16 entradas lógicas por meio de uma conexão com borne de parafuso removível e uma interface de barramento de expansão TM3.\u003c\/p\u003e\n\u003ch3\u003eEspecificações de hardware\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003eTM3DI16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de produto\u003c\/td\u003e\n\u003ctd\u003eMódulo de entradas discretas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinha de produtos\u003c\/td\u003e\n\u003ctd\u003eModicon TM3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControladores compatíveis\u003c\/td\u003e\n\u003ctd\u003eModicon M221, M241, M251, M262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntradas discretas\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão de entrada\u003c\/td\u003e\n\u003ctd\u003e24 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLógica de entrada\u003c\/td\u003e\n\u003ctd\u003eDreno ou fonte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorma de entrada\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2 Tipo 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente de entrada\u003c\/td\u003e\n\u003ctd\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão do estado 1\u003c\/td\u003e\n\u003ctd\u003e15-28.8 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão do estado 0\u003c\/td\u003e\n\u003ctd\u003e0-5 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente do estado 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente do estado 0\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedância de entrada\u003c\/td\u003e\n\u003ctd\u003e3.4 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo de resposta da entrada\u003c\/td\u003e\n\u003ctd\u003e4 ms máximo, ativação; 4 ms máximo, desativação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentação do sensor\u003c\/td\u003e\n\u003ctd\u003e19.2-28.8 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo típico de corrente do barramento\u003c\/td\u003e\n\u003ctd\u003e34 mA a 5 VCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConexão elétrica\u003c\/td\u003e\n\u003ctd\u003eBloco de bornes de parafuso removível, passo de 3.81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistância máxima do cabo\u003c\/td\u003e\n\u003ctd\u003e50 m para entrada comum com cabo não blindado\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolamento entre canal e barramento\u003c\/td\u003e\n\u003ctd\u003e500 VCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicação local\u003c\/td\u003e\n\u003ctd\u003e1 LED verde por canal de entrada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMontagem\u003c\/td\u003e\n\u003ctd\u003eTrilho DIN TH35-15 ou TH35-7.5, placa ou painel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensões\u003c\/td\u003e\n\u003ctd\u003e27.4 x 84.6 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrau de proteção IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de operação\u003c\/td\u003e\n\u003ctd\u003e-10 a 35 deg C na vertical; -10 a 55 deg C na horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de armazenamento\u003c\/td\u003e\n\u003ctd\u003e-25 a 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidade relativa\u003c\/td\u003e\n\u003ctd\u003e10-95%, sem condensação\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude de operação\u003c\/td\u003e\n\u003ctd\u003e0-2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFonte de alimentação\u003c\/td\u003e\n\u003ctd\u003eBarramento TM3 interno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificações\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, UKCA, RCM, EAC, cULus HazLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorma\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigem\u003c\/td\u003e\n\u003ctd\u003eTW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissões de carbono do ciclo de vida\u003c\/td\u003e\n\u003ctd\u003e20 kg CO2 eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3606480611384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eComunicação do barramento TM3 e expansão de E\/S\u003c\/h3\u003e\n\u003cp\u003eO TM3DI16 recebe alimentação e dados do módulo por meio do barramento de expansão TM3 interno quando montado com controladores Modicon e módulos de E\/S TM3 compatíveis. A densidade de entrada de 16 canais permite concentrar vários sinais discretos de campo em um conjunto de expansão compacto. O módulo usa um bloco de bornes removível para a fiação de campo e fornece indicação individual por LED verde do estado da entrada.\u003c\/p\u003e\n\u003cp\u003eA interface de entrada aceita lógica de dreno ou fonte e fornece isolamento de 500 VCA entre os canais e o barramento. O tempo de resposta máximo especificado de 4 ms para ativação e desativação define a resposta do processamento de sinais digitais do módulo.\u003c\/p\u003e\n\u003ch3\u003ePerguntas frequentes (FAQ)\u003c\/h3\u003e\n\u003cp\u003eP: Quais controladores são compatíveis com o TM3DI16?\u003c\/p\u003e\n\u003cp\u003eR: O TM3DI16 é especificado para os controladores Modicon M221, M241, M251 e M262 como parte do sistema de expansão de E\/S TM3.\u003c\/p\u003e\n\u003cp\u003eP: Qual é a faixa elétrica de entrada?\u003c\/p\u003e\n\u003cp\u003eR: O módulo opera com uma alimentação de entrada nominal de 24 VCC. O estado lógico 1 é garantido de 15 a 28.8 VCC, enquanto o estado lógico 0 é especificado de 0 a 5 VCC.\u003c\/p\u003e\n\u003cp\u003eP: Como o TM3DI16 é montado e conectado?\u003c\/p\u003e\n\u003cp\u003eR: Ele pode ser montado em trilho DIN TH35-15 ou TH35-7.5, ou em uma placa ou painel usando o kit de fixação apropriado. Os sinais de campo são conectados por meio do bloco de bornes de parafuso removível.\u003c\/p\u003e\n\u003ch3\u003eDiretrizes de instalação em campo\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonte o módulo em um trilho DIN TH35 compatível com a IEC 60715 ou em uma configuração de montagem em painel aprovada.\u003c\/li\u003e\n\u003cli\u003eInstale o módulo em um invólucro compatível com seu grau de proteção IP20.\u003c\/li\u003e\n\u003cli\u003eConecte os sinais discretos de 24 VCC de acordo com a configuração de entrada de dreno ou fonte necessária.\u003c\/li\u003e\n\u003cli\u003eMantenha a fiação dos sinais discretos separada dos condutores de alimentação de alta tensão e de comutação com alto nível de ruído, sempre que possível.\u003c\/li\u003e\n\u003cli\u003eUse a faixa especificada de condutores do bloco de bornes e mantenha conexões seguras nos bornes.\u003c\/li\u003e\n\u003cli\u003ePara trechos próximos do máximo especificado de 50 m, verifique a queda de tensão e as condições de ruído elétrico antes do comissionamento.\u003c\/li\u003e\n\u003cli\u003eUse os LEDs dos canais do módulo para verificar o estado das entradas de campo durante o comissionamento.\u003c\/li\u003e\n\u003cli\u003eMantenha o intertravamento mecânico TM3 e a conexão do barramento de expansão ao montar módulos adjacentes.\u003c\/li\u003e\n\u003cli\u003eSiga a documentação de instalação do controlador e do sistema TM3 para práticas de aterramento, blindagem e fiação do painel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67655738917106,"sku":"TM3DI16","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/TM3DI16K2.jpg?v=1791456027","url":"https:\/\/www.petrospare.com\/pt\/products\/schneider-electric-tm3di16-modicon-tm3-discrete-input-module-1","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}