{"product_id":"yokogawa-ycb141-m025-v-net-cable","title":"Yokogawa YCB141-M025 V net Cable","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa YCB141-M025\u003c\/strong\u003e is a 25 m V net cable specified for Yokogawa control system network connections using the 10BASE-2 cable format. The YCB141 model is used as a V net or ER Bus cable, with cable length selected through the suffix code. Yokogawa specifies this cable for V net applications and notes that V net specifications differ from standard Ethernet specifications.\u003c\/p\u003e\n\u003ch3\u003eCable Configuration\u003c\/h3\u003e\n\u003cp\u003eYCB141 is a Yokogawa-specified coaxial cable used for V net-related connections. The \u003cstrong\u003e-M025\u003c\/strong\u003e suffix specifies a nominal cable length of 25 m. The model family provides lengths in 5 m increments beyond the shorter standard lengths, with a maximum specified length of 185 m.\u003c\/p\u003e\n\u003cp\u003eThe cable has an approximately 5 mm conductor\/cable core dimension and 14.5 mm outer diameter according to the Yokogawa dimensional drawing. The minimum bending radius is 50 mm, which should be considered when routing the cable in cabinets or between network connection points.\u003c\/p\u003e\n\u003ch3\u003eV net Application\u003c\/h3\u003e\n\u003cp\u003eYokogawa identifies YCB141 as a \u003cstrong\u003eV net or ER Bus Cable\u003c\/strong\u003e in CENTUM system documentation. The 10BASE-2 terminology is used to indicate the cable format only; Yokogawa explicitly states that V net specifications are different from Ethernet specifications. Therefore, YCB141 should be treated as a designated Yokogawa V net cable rather than substituted solely on the basis of a generic 10BASE-2 cable description.\u003c\/p\u003e\n\u003ch3\u003eParameter | Specification\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB141-M025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eV net Cable (10BASE-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e25 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eYokogawa-specified 10BASE-2 coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e185 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bending Radius\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e14.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore\/Cable Dimension\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe base model \u003cstrong\u003eYCB141\u003c\/strong\u003e identifies the V net Cable (10BASE-2). The suffix \u003cstrong\u003e-M025\u003c\/strong\u003e specifies a 25 m cable length. Yokogawa documentation lists YCB141 lengths such as 1 m, 2 m, 5 m and 10 m, followed by selectable lengths in 5 m increments up to 185 m.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the -M025 suffix mean on YCB141-M025?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003cstrong\u003e-M025\u003c\/strong\u003e suffix specifies a cable length of 25 m. The YCB141 model uses the suffix code to select the required cable length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is YCB141-M025 a standard Ethernet cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Although Yokogawa uses the term 10BASE-2 to describe the cable format, the manufacturer specifically notes that V net specifications differ from Ethernet specifications. YCB141 is intended as a Yokogawa-specified V net cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What temperature range is specified for YCB141?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa specifies use of the YCB141 cable within \u003cstrong\u003e-20 to 70 deg C\u003c\/strong\u003e. The minimum bending radius is 50 mm. \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69383705526514,"sku":"YCB141-M025","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/YCB141-M0251.jpg?v=1794983488","url":"https:\/\/www.petrospare.com\/products\/yokogawa-ycb141-m025-v-net-cable","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}