{"product_id":"yokogawa-ut32a-010-11-00-digital-indicating-controller","title":"Yokogawa UT32A-010-11-00 Digital Indicating Controller","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa UT32A-010-11-00\u003c\/strong\u003e is a digital indicating controller from Yokogawa's UTAdvanced series. It is designed for process measurement, display and control, providing a panel-mounted interface for monitoring process variables and managing control outputs. Its exact input, output and communication configuration should be checked against the complete model code before replacement or procurement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Measurement Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe UT32A accepts a universal process input, supporting thermocouples (TC), resistance temperature detectors (RTD), millivolt, voltage and current signals. It converts the measured process variable (PV) into a displayed value and uses the configured control algorithm to regulate the process toward the setpoint (SP).\u003c\/p\u003e\n\u003cp\u003eThe controller supports PID and ON\/OFF control, including continuous and time-proportional PID operation. Heating\/cooling and position-proportional control are also available within the UT32A product family; these functions should not be assumed to be enabled on every model configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Signal Handling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e-010\u003c\/strong\u003e model configuration is identified as the standard control type with RS-485 communication. The UT32A communication interface supports serial data exchange with compatible supervisory or control equipment. The communication option is distinct from the controller's measurement input and control output circuits.\u003c\/p\u003e\n\u003cp\u003eStandard UT32A specifications include digital inputs for functions such as setpoint selection and automatic\/manual switching, and digital outputs for alarm or status functions. The actual signal allocation should be checked against the controller's configured output specification.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT32A-010-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Indicating Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUTAdvanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 38.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire or 4-wire, subject to configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Input\u003c\/td\u003e\n\u003ctd\u003eUniversal input: TC, RTD, mV, V, mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndication Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Scan Period\u003c\/td\u003e\n\u003ctd\u003e200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-digit, 14-segment color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Digital Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Digital Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Algorithms\u003c\/td\u003e\n\u003ctd\u003ePID, ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC standard supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the UT32A-010-11-00 support RS-485 communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The model includes the RS-485 communication function, supporting communication speeds up to 38.4 kbps. Two-wire or four-wire communication arrangements are supported, subject to the applicable configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input signals can the UT32A accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Its universal measurement input supports thermocouples, RTDs, mV, voltage and current signals. The input type must be configured for the connected sensor or transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this controller perform heating and cooling control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Heating\/cooling control is available in the UT32A family, but it is a separately identified control configuration. The UT32A-010-11-00 is identified as a standard control type, not the heating\/cooling version.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69309699784946,"sku":"UT32A-010-11-00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/UT32A-010-11-002.jpg?v=1794538842","url":"https:\/\/www.petrospare.com\/products\/yokogawa-ut32a-010-11-00-digital-indicating-controller","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}