{"product_id":"yokogawa-ssc50d-f2524-duplexed-safety-control-unit","title":"Yokogawa SSC50D-F2524 Duplexed Safety Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SSC50D-F2524\u003c\/strong\u003e is a duplexed Safety Control Unit for the ProSafe-RS Safety Instrumented System (SIS), using Vnet\/IP communication. It provides redundant processor and power supply configurations for safety logic execution. The F-type configuration supports an extended ambient temperature range and includes a fan unit. Its ordering code specifies a 220-240 V AC power supply and no explosion protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SSC50D-F2524 serves as the control hardware in a ProSafe-RS Safety Control Station (SCS). Its duplexed architecture uses two processor modules to execute safety control functions, with redundant Vnet\/IP and ESB bus interfaces for communication with the control network and connected safety node units.\u003c\/p\u003e\n\u003cp\u003eThe unit supports up to eight I\/O modules per safety control unit and up to nine connected safety node units. The ESB bus provides the communication path between the control unit and distributed safety node hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSSC50D-F2524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplexed Safety Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMIPS R5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVnet\/IP Communication Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbps, full duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface Standard\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Cable\u003c\/td\u003e\n\u003ctd\u003eUTP, CAT5e or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Network Distance\u003c\/td\u003e\n\u003ctd\u003e100 m to Layer 2 switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e290 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 per control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Node Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 9 per control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Code Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the hardware configuration as follows:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSC50D\u003c\/td\u003e\n\u003ctd\u003eDuplexed Safety Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-F\u003c\/td\u003e\n\u003ctd\u003eWide-range temperature type, -20 to 70 deg C, with fan unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eWithout Safety Control Function License (R4.01.31 or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe final code 4 is a software licensing configuration, not a power supply specification. For R4.01.31 and later, the required patch software must be applied.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SSC50D-F uses a fan unit for operation above 40 deg C ambient temperature. The wide-temperature configuration requires twelve M5 rack-mounting screws. Power supply and grounding connections use M4 screws.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's hardware specification also identifies SEC401 ESB bus coupler modules for installation in the seventh and eighth slots when connecting safety node units.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SSC50D-F2524 include a Safety Control Function License?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The final suffix 4 identifies the configuration without the Safety Control Function License for R4.01.31 or later. The required software license must be specified separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between SSC50D-F2524 and the standard-temperature configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The F configuration supports an ambient temperature range of -20 to 70 deg C and includes a fan unit. The standard S configuration supports -20 to 40 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SSC50D-F2524 support explosion-protected installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The suffix 5 specifies a configuration without explosion protection. It should not be treated as an explosion-protected model. Cabinet and installation requirements must follow the applicable ProSafe-RS installation guidance. \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69369840140530,"sku":"SSC50D-F2524","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SSC50D-S21212.jpg?v=1792481607","url":"https:\/\/www.petrospare.com\/products\/yokogawa-ssc50d-f2524-duplexed-safety-control-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}