{"product_id":"yokogawa-snb10d-425-cu2t-safety-node-unit","title":"Yokogawa SNB10D-425\/CU2T Safety Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SNB10D-425\/CU2T\u003c\/strong\u003e is a rack-mountable Safety Node Unit designed for Yokogawa's ProSafe-RS safety instrumented system. It provides the interface between field I\/O modules and the safety control unit through the ESB bus. This configuration includes dual-redundant power supplies, a 220-240 V AC power input, and an ESB bus connector unit with an integrated terminator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SNB10D provides the node-level interface for distributed safety I\/O. It accommodates I\/O modules and transfers their signals to the safety control unit through the ESB bus. The node also distributes power to the installed I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe \/CU2T option identifies a connector unit with an ESB bus terminator. It is intended for an end node in the ESB bus connection, distinguishing it from the \/CU2N version, which uses a connector unit without the terminator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code identifies the following hardware configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-4:\u003c\/strong\u003e Dual-redundant power supply configuration, for ProSafe-RS R4.01 or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2:\u003c\/strong\u003e 220 to 240 V AC power supply, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e ISA Standard G3 and operating temperature specification of -20 to 70 deg C, without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/CU2T:\u003c\/strong\u003e ESB bus connector unit with terminator, part number S9343FA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \/CU2T configuration is relevant when selecting the node position in the ESB bus arrangement. The terminator distinguishes this version from the \/CU2N configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSNB10D-425\/CU2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Connector\u003c\/td\u003e\n\u003ctd\u003eS9343FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Termination\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eWithout explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 37.75 x 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Fixings\u003c\/td\u003e\n\u003ctd\u003eFour M5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd\u003e4 insulating bushes, S9049PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eSource: Yokogawa General Specifications GS 32Q06K10-31E.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eESB Bus and I\/O Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SNB10D accommodates two power supply modules and two ESB bus interface modules (SSB401). The power supply modules provide power to the installed I\/O modules, while the ESB interface modules handle communication with the safety control unit.\u003c\/p\u003e\n\u003cp\u003eThe maximum number of connectable safety nodes depends on the ESB bus coupler:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to \u003cstrong\u003e13 safety node units\u003c\/strong\u003e with the SEC402 ESB bus coupler on S2SC70S, S2SC70D, SSC60S or SSC60D safety control units.\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e9 safety node units\u003c\/strong\u003e with the SEC401 ESB bus coupler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese limits apply to the specified system configurations and should be checked against the installed safety controller and bus coupler.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Connection Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SNB10D is designed for 19-inch rack mounting and is secured with four M5 screws. The supplied insulating bushes are used during mounting.\u003c\/p\u003e\n\u003cp\u003eFor connection to the safety control unit, Yokogawa specifies a YCB301 ESB bus cable with a minimum length of 1 m. The rack-mountable equipment must be installed in a keyed metallic cabinet to meet the applicable safety and EMC installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between SNB10D-425\/CU2T and SNB10D-425\/CU2N?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both use the same SNB10D node configuration. The \/CU2T version includes an ESB bus connector unit with a terminator, while \/CU2N uses a connector unit without a terminator. The correct version depends on the node's position in the ESB bus arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does SNB10D-425\/CU2T support redundant power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -4 suffix specifies a dual-redundant power supply configuration for ProSafe-RS R4.01 or later. The node configuration includes two power supply modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all I\/O module slots be populated freely?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Yokogawa specifies restrictions on I\/O module quantities and slot positions. Unused I\/O module slots must be fitted with SDCV01 dummy covers. The applicable I\/O module mounting requirements should be checked before configuring the node. \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69368909889778,"sku":"SNB10D-425\/CU2T","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SNB10D-425_1.jpg?v=1766976190","url":"https:\/\/www.petrospare.com\/products\/yokogawa-snb10d-425-cu2t-safety-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}