{"product_id":"yokogawa-sed2d-11-digital-terminal-board","title":"Yokogawa SED2D-11 Digital Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SED2D-11\u003c\/strong\u003e is a digital terminal board designed for single or dual-redundant digital I\/O configurations in the ProSafe-RS system. It provides field wiring termination through M4 screw terminals and interfaces with the SDV521 digital I\/O module through an AKB651 connection cable. Its four-channel-by-four arrangement supports organized termination of digital signal circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SED2D terminal board provides the physical connection between field wiring and the associated digital I\/O module. It organizes field signal connections into four groups, each serving four channels, for a total arrangement of 16 channel connections.\u003c\/p\u003e\n\u003cp\u003eFor the documented ProSafe-RS configuration, the SED2D connects to the SDV521 through an AKB651 cable. The terminal board handles field-side wiring, while the connected I\/O module performs the digital signal processing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRedundant Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SED2D supports both single and dual-redundant configurations. When the I\/O module is duplexed, the corresponding connector pairs must be used: CN1 and CN2, CN3 and CN4, CN5 and CN6, or CN7 and CN8.\u003c\/p\u003e\n\u003cp\u003eThis connector arrangement provides the wiring interface for redundant I\/O connections. The installation must follow the designated connector pairing rather than using only one connector from a pair.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSED2D-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSingle or dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Points\u003c\/td\u003e\n\u003ctd\u003e4 channels x 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Module\u003c\/td\u003e\n\u003ctd\u003eSDV521\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Cable\u003c\/td\u003e\n\u003ctd\u003eAKB651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 MOhm minimum at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified withstand voltage of 2000 V AC for one minute is measured between the input signal terminals and the board case. The minimum insulation resistance of 100 MOhm is measured at 500 V DC. These values describe the board's electrical insulation characteristics and should not be confused with the operating voltage of the connected digital output circuits.\u003c\/p\u003e\n\u003cp\u003eFor field wiring, the M4 screw terminals provide mechanical connections for crimping terminals. Yokogawa's connection guidance specifies a recommended conductor cross-section of 0.5 mm2 to 2 mm2 (AWG 20 to 14) for M4 crimping terminals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which digital I\/O module is specified for the SED2D terminal board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented ProSafe-RS configuration pairs the SED2D with the SDV521 digital output module using the AKB651 dedicated signal cable. This combination is specified for 4-channel digital output applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SED2D be used in a dual-redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The SED2D supports single and dual-redundant configurations. For duplexed I\/O connections, use the designated connector pairs CN1\/CN2, CN3\/CN4, CN5\/CN6 or CN7\/CN8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing an existing SED2D-11?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the complete model designation, terminal board configuration, connected SDV521 module and AKB651 cable arrangement. Also verify the existing redundant wiring and field terminal connections before replacement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69396394049778,"sku":"SED2D-11","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SED4D-01_2.jpg?v=1770718198","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sed2d-11-digital-terminal-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}