{"product_id":"yokogawa-sdv144-s13-d4a00-s2-digital-input-module","title":"Yokogawa SDV144-S13\/D4A00 S2 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SDV144-S13\/D4A00 S2\u003c\/strong\u003e is a 16-channel digital input module designed to receive contact status signals from field devices and transfer their states to a control system. It supports 24 V DC no-voltage contact inputs and provides module-level isolation between the field input circuits and the system. The SDV144 platform is used for digital status acquisition in Yokogawa control and safety-related automation configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Function and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SDV144 receives discrete signals from external dry contacts, such as relay contacts and field status switches. Each input channel detects the contact state and converts it into digital information for the control system.\u003c\/p\u003e\n\u003cp\u003eThe module uses a 24 V DC sensing circuit. Its input resistance thresholds distinguish closed and open contact conditions, while the module isolation separates the field-side input circuits from the system side. This arrangement supports the acquisition of multiple independent equipment status signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSDV144-S13\/D4A00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eNo-voltage contact (dry contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6 mA +\/- 20% at 24 V DC, 0 ohm input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Resistance\u003c\/td\u003e\n\u003ctd\u003e1 k ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Resistance\u003c\/td\u003e\n\u003ctd\u003e100 k ohm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Instantaneous Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e40 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Current Capacity\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC: 290 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC: 140 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eModule isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC, input signal to system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SDV144 is intended for voltage-free contact signals rather than direct measurement of externally powered voltage signals. The specified ON and OFF resistance thresholds define the electrical conditions used to recognize contact closure and opening.\u003c\/p\u003e\n\u003cp\u003eThe external 24 V DC supply provides the input sensing circuit with its required operating power. The 30 V DC instantaneous input limit should be observed when checking field wiring and external signal conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SDV144-S13 be connected directly to dry-contact field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is designed for no-voltage contact inputs. Field contacts must meet the specified input resistance and contact electrical requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital input signals can one module handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The SDV144 provides 16 input channels. Each channel is used to acquire a discrete contact state for system monitoring or control logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the SDV144 a digital output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. It is a digital input module. It receives external contact signals and reports their states to the control system; it does not provide switched output power to field loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Isolation and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SDV144 supports dual-redundant configuration in compatible Yokogawa system architectures. This allows contact status acquisition to be configured with redundant modules where the application design requires it. Redundancy is a system configuration feature and should not be interpreted as an automatic property of a single module.\u003c\/p\u003e\n\u003cp\u003eThe specified withstand voltage is \u003cstrong\u003e2 kV AC for one minute\u003c\/strong\u003e between the input signal and system, with all 16 input lines connected collectively. This rating applies under the manufacturer's stated test conditions. Yokogawa recommends a floating field power supply for higher noise immunity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Wiring and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor applications requiring field wiring fault detection, Yokogawa specifies optional SCB100 and SCB110 diagnostic elements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCB100:\u003c\/strong\u003e Supports open-circuit detection when the normal input state is OFF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCB110:\u003c\/strong\u003e Supports short-circuit detection when the normal input state is ON.\u003c\/li\u003e\n\u003cli\u003eBoth elements can be used together when both open- and short-circuit detection are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese components are additional field wiring elements, not built-in diagnostic functions that should be assumed to be present in every SDV144 installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification and Ordering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SDV144-S13 is documented as a 16-channel digital input module with ISA Standard G3 compatibility and a specified operating temperature range of -20 to 70 deg C. The manufacturer identifies pressure-clamp terminal, MIL cable and dedicated signal cable connection arrangements for this module family.\u003c\/p\u003e\n\u003cp\u003eThe complete ordering reference supplied for this product is \u003cstrong\u003eSDV144-S13\/D4A00 S2\u003c\/strong\u003e. The \/D4A00 option and S2 designation should be retained when checking replacement stock and nameplate identification.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69350861570290,"sku":"SDV144-S13\/D4A00 S2","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SDV144-S13D4A00S22.jpg?v=1794798566","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sdv144-s13-d4a00-s2-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}