{"product_id":"yokogawa-sarm55w-mechanical-relay-board","title":"Yokogawa SARM55W Mechanical Relay Board","description":"\u003cp\u003eThe Yokogawa \u003cstrong\u003eSARM55W\u003c\/strong\u003e is a 32-point mechanical relay board designed for wet contact digital output applications in Yokogawa process control systems. It provides the field-side relay interface for digital output modules, allowing external devices to be switched using separately supplied field power. The board supports single or dual-redundant configurations and uses M4 screw terminals for field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSARM55W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eWet Contact Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e250 V AC, 0.6 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e30 V DC, 0.6 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e125 V DC, 0.1 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load\u003c\/td\u003e\n\u003ctd\u003e5 V, 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, maximum 0.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply\u003c\/td\u003e\n\u003ctd\u003eDual-line, one supply group per 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV between field terminals and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V between 24 V power terminals and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV between 24 V power terminals and field terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SARM55W uses mechanical relays to convert digital output commands from the control system into wet contact switching signals for field devices. Unlike a dry-contact board, it receives external field power and supplies powered contact outputs to connected loads.\u003c\/p\u003e\n\u003cp\u003eThe 32 output points are divided into two groups:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannels 1-16: First field power supply group.\u003c\/li\u003e\n\u003cli\u003eChannels 17-32: Second field power supply group.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach group has a separate field power supply connection. The internal relay circuit requires an independent 24 V DC supply, separate from the field-device power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModule and Cable Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa specification identifies the following connections for the ARM55W relay board:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eCompatible Model\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e32-point Digital Output Module\u003c\/td\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e64-point Digital Output Module\u003c\/td\u003e\n\u003ctd\u003eADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eATD5A (with ADV551)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32-point Signal Cable\u003c\/td\u003e\n\u003ctd\u003eAKB331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e64-point Signal Cable\u003c\/td\u003e\n\u003ctd\u003eAKB337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFor an ADV561 64-point configuration, two relay boards and two AKB337 signal cables are required. The ADV551 configuration uses one 32-point relay board and the ATD5A terminal block.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Wiring and Load Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe M4 screw terminals provide the field-device connections. The maximum switching load depends on the voltage type, so the connected load must remain within the corresponding AC or DC rating.\u003c\/p\u003e\n\u003cp\u003eFor inductive loads, Yokogawa specifies an external noise protection circuit connected in parallel with the load:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC loads: RC protection circuit.\u003c\/li\u003e\n\u003cli\u003eDC loads: Diode protection circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese measures help suppress switching transients that can affect relay contacts and connected circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ARM55W and ARM55D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ARM55W provides wet contact outputs with an external field power supply. ARM55D provides dry contact outputs without the field power supply arrangement. Their maximum contact load ratings also differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the board be used with the ADV561 digital output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The documented 64-point configuration requires two ARM55W boards and two AKB337 signal cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the board require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The internal relay circuit requires 24 V DC, with a maximum current consumption of 0.65 A. Separate field power supplies are also required for the two 16-point output groups.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69452983075058,"sku":"SARM55W","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SARM55C.jpg?v=1795422691","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sarm55w-mechanical-relay-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}