{"product_id":"yokogawa-sarm55c-mechanical-relay-output-board","title":"Yokogawa SARM55C Mechanical Relay Output Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SARM55C\u003c\/strong\u003e, corresponding to the \u003cstrong\u003eARM55C\u003c\/strong\u003e mechanical relay board designation, provides 32-point dry-contact switching for digital output signals in the Yokogawa CENTUM VP Field Control I\/O (FIO) subsystem. It interfaces ADV551 or ADV561 digital output modules with field devices, supporting normally open (NO) or normally closed (NC) contact configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSARM55C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eARM55C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Output Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm (W) x 132.5 mm (H), 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, max. 0.85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eMechanical relay dry-contact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eNO or NC, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 1.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load\u003c\/td\u003e\n\u003ctd\u003e5 V, 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eADV551, ADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eATD5A (for ADV551 configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Cables\u003c\/td\u003e\n\u003ctd\u003eAKB331 (32-point), AKB337 (64-point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eM3.5 screws; M4 for power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 Mohm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (field terminals to case); 500 V AC (power terminals to case); 2 kV AC (field terminals to power terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eSpecifications are based on Yokogawa's FIO relay board documentation for ARM55C. The SARM55C designation is used in supplier listings; confirm the physical nameplate when matching replacement hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Relay Switching and Electrical Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SARM55C uses mechanical relay contacts to convert digital output commands from the ADV551 or ADV561 module into field-side dry-contact switching signals.\u003c\/p\u003e\n\u003cp\u003eEach of the 32 channels operates through an individual relay contact. The output can be configured as an a-contact (NO) or b-contact (NC), depending on the required field circuit arrangement.\u003c\/p\u003e\n\u003cp\u003eThe board uses a separate 24 VDC supply for its internal relay circuitry, with a maximum current consumption of 0.85 A. This supply is distinct from the external field load circuit.\u003c\/p\u003e\n\u003cp\u003eElectrical isolation specifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum insulation resistance of 10 Mohm at 500 VDC.\u003c\/li\u003e\n\u003cli\u003e2 kV AC withstand voltage between field terminals and the case.\u003c\/li\u003e\n\u003cli\u003e500 V AC withstand voltage between 24 V power terminals and the case.\u003c\/li\u003e\n\u003cli\u003e2 kV AC withstand voltage between field terminals and 24 V power terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor inductive loads, Yokogawa specifies an RC protection circuit for AC loads or a diode for DC loads connected in parallel with the load. This limits switching noise generated by inductive energy during relay contact operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SARM55C operate with both ADV551 and ADV561 digital output modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ARM55C relay board is specified for both ADV551 (32-point DO) and ADV561 (64-point DO) configurations. The ADV551 configuration uses the ATD5A terminal block. The ADV561 configuration requires two relay boards and two AKB337 signal cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SARM55C support normally open and normally closed outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each relay output can be configured as an a-contact (NO) or b-contact (NC). The required contact arrangement must be selected according to the field wiring design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical protection is required when connecting inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For AC inductive loads, connect an RC protection circuit in parallel with the load. For DC inductive loads, use a diode protection circuit. Observe the specified maximum contact load of 30 VDC and 1.5 A per point.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eMounting:\u003c\/strong\u003e Install the relay board in the designated FIO cabinet or rack position. Verify the 3U mounting space and mechanical fixing points.\u003c\/p\u003e\n\u003cp\u003e2. \u003cstrong\u003eSignal Connections:\u003c\/strong\u003e Use the specified AKB331 or AKB337 signal cable according to the connected digital output module configuration.\u003c\/p\u003e\n\u003cp\u003e3. \u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Connect the external 24 VDC supply for the internal relay circuit. Verify polarity and supply capacity before energizing.\u003c\/p\u003e\n\u003cp\u003e4. \u003cstrong\u003eField Terminations:\u003c\/strong\u003e Use the specified M3.5 screw terminals for field connections and M4 terminals for the power input section. Ensure correct crimp terminal dimensions.\u003c\/p\u003e\n\u003cp\u003e5. \u003cstrong\u003eLoad Protection:\u003c\/strong\u003e Install suitable suppression components across inductive loads to reduce switching transients and contact interference.\u003c\/p\u003e\n\u003cp\u003e6. \u003cstrong\u003eElectrical Inspection:\u003c\/strong\u003e Check terminal tightness, insulation condition, contact configuration and field wiring continuity before commissioning.\u003c\/p\u003e\n\u003cp\u003e7. \u003cstrong\u003eFunctional Testing:\u003c\/strong\u003e Test each output channel against the corresponding ADV551 or ADV561 command and verify the expected NO\/NC contact behavior.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69452978815218,"sku":"SARM55C","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SARM55C2.jpg?v=1795422691","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sarm55c-mechanical-relay-output-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}