{"product_id":"yokogawa-sarm15a-mechanical-relay-contact-input-board","title":"Yokogawa SARM15A Mechanical Relay Contact Input Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SARM15A\u003c\/strong\u003e, also identified with the \u003cstrong\u003eARM15A\u003c\/strong\u003e mechanical relay contact input board designation, provides a 32-point interface for acquiring dry-contact signals in the Yokogawa CENTUM VP Field Control Unit (FIO) subsystem. It connects field contact devices to ADV-series digital input modules through mechanical relay circuits, with M4 screw terminals and external 24 V DC power distribution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSARM15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated Hardware Designation\u003c\/td\u003e\n\u003ctd\u003eARM15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Contact Input Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC, maximum 0.32 A (internal circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Threshold\u003c\/td\u003e\n\u003ctd\u003e150 ohms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Threshold\u003c\/td\u003e\n\u003ctd\u003e200 kohms or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Contact Minimum Load\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply\u003c\/td\u003e\n\u003ctd\u003eDual-line 24 V DC, maximum 0.3 A per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible DI Modules\u003c\/td\u003e\n\u003ctd\u003eADV151 (32-point), ADV161 (64-point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Cable\u003c\/td\u003e\n\u003ctd\u003eAKB331 (32-point), AKB337 (64-point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 Mohms at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV between field terminals and case; 500 V between power terminals and case; 1.5 kV between power and field terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003etek-international.com+2\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Relay Contact Interface and Power Distribution\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SARM15A uses mechanical relay contacts to interface field-side dry-contact signals with the CENTUM VP digital input subsystem. The input state is determined by contact resistance: 150 ohms or less represents the ON condition, while 200 kohms or greater represents the OFF condition.\u003c\/p\u003e\n\u003cp\u003eIts 32 input points are arranged with dual-line field power distribution, supplying 24 V DC to each group of 16 points. Each line supports a maximum current of 0.3 A. The internal circuit requires a separate 24 V DC supply with a maximum current consumption of 0.32 A.\u003c\/p\u003e\n\u003cp\u003eThe electrical isolation specifications define the separation between field terminals, power terminals, and the board enclosure. These ratings should be considered when checking grounding arrangements and field wiring insulation.\u003c\/p\u003e\n\u003cp\u003etek-international.com+1\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SARM15A operate with redundant digital input modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports single and dual-redundant configurations. For an ADV161 64-point input module, two ARM15A relay boards and two AKB337 signal cables are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the electrical input threshold for detecting contact states?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ON state requires a contact resistance of 150 ohms or less. The OFF state requires at least 200 kohms. Field contact ratings must satisfy the specified minimum load of 24 V DC at 13 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the SARM15A support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping capability is not established by the available technical specifications. Isolate the relevant power supplies and follow the Yokogawa system maintenance procedure before removing or replacing the board.\u003c\/p\u003e\n\u003cp\u003etek-international.com+1\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Install the board in the designated 19-inch rack position, allowing sufficient clearance for cable routing and maintenance access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring:\u003c\/strong\u003e Connect field dry-contact signals to the M4 screw terminals. Check terminal assignments against the Yokogawa connection diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Provide the specified external 24 V DC supply for the internal circuit and separate field power connections. Observe the maximum current rating of each supply line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Connection:\u003c\/strong\u003e Use AKB331 for the 32-point ADV151 configuration. For ADV161 applications, verify the required dual-board and AKB337 cable arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Connect the board chassis to the designated cabinet grounding system. Terminate cable shields according to the system grounding design to avoid unintended ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Verification:\u003c\/strong\u003e Check field contact resistance, supply polarity, terminal tightness, and insulation before energizing the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Verify all 32 input states through the connected digital input module and confirm correct signal transitions from the field devices.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69452926484722,"sku":"SARM15A","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SARM15A.jpg?v=1795422542","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sarm15a-mechanical-relay-contact-input-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}