{"product_id":"yokogawa-sarm15a-000-mechanical-relay-input-board","title":"Yokogawa SARM15A-000 Mechanical Relay Input Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SARM15A-000\u003c\/strong\u003e is identified as a mechanical relay input board for industrial control system signal interfacing. The corresponding Yokogawa ARM15A technical specification describes a 32-point contact input arrangement for acquiring field contact signals and routing them to digital input modules. Its design includes M4 field terminals and external 24 V DC power connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board provides an interface between external mechanical contacts and the control system's digital input modules. It supports \u003cstrong\u003e32 contact points\u003c\/strong\u003e and can be configured for single or dual-redundant contact input arrangements.\u003c\/p\u003e\n\u003cp\u003eEach input is evaluated according to the resistance of the external contact circuit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eON state: Contact resistance of 150 ohms or less.\u003c\/li\u003e\n\u003cli\u003eOFF state: Contact resistance of at least 200 kohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis resistance-based input arrangement allows field switches and relay contacts to be monitored as discrete status signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Connections and Power Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe field devices connect through M4 screw terminals. The board requires external 24 V DC power for its internal circuitry and field-device contact supply.\u003c\/p\u003e\n\u003cp\u003eThe field-device supply uses a dual-line arrangement, with power distributed across groups of 16 contact points. This arrangement should be considered when planning external power distribution and field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible I\/O Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ARM15A technical specification identifies the following associated digital input modules and signal cables:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eADV151: 32-point digital input module, used with the ATD5A terminal block.\u003c\/li\u003e\n\u003cli\u003eADV161: 64-point digital input module.\u003c\/li\u003e\n\u003cli\u003eAKB331: Signal cable for 32-point connections.\u003c\/li\u003e\n\u003cli\u003eAKB337: Signal cable for 64-point connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor one ADV161, the specified configuration requires two relay boards and two AKB337 signal cables. Confirm the exact hardware configuration against the installed FIO system before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSARM15A-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Input Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle \/ Dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Signal\u003c\/td\u003e\n\u003ctd\u003e150 ohms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Signal\u003c\/td\u003e\n\u003ctd\u003eAt least 200 kohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Device Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Contact Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 13 mA minimum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Current\u003c\/td\u003e\n\u003ctd\u003eMax. 0.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Device Supply\u003c\/td\u003e\n\u003ctd\u003eDual-line, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Supply Current\u003c\/td\u003e\n\u003ctd\u003eMax. 0.3 A per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 Mohms at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC (field terminals to case); 500 V AC (power terminals to case); 1.5 kV AC (power terminals to field terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90 %RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm (W) x 132.5 mm (H), 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field signals does the SARM15A-000 handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is specified for mechanical relay contact input. Field contact status is distinguished by resistance thresholds: 150 ohms or less for ON and at least 200 kohms for OFF.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Yokogawa digital input modules are associated with this relay board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ARM15A specification identifies ADV151 and ADV161. The corresponding signal cables are AKB331 and AKB337, respectively, subject to the specified channel configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the board require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The specified configuration requires 24 V DC for the internal circuit and a separate field-device contact supply arrangement. The maximum internal circuit current is 0.32 A, while each field supply line supports up to 0.3 A.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69350921371890,"sku":"SARM15A-000","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SARM15A-000.jpg?v=1794798848","url":"https:\/\/www.petrospare.com\/products\/yokogawa-sarm15a-000-mechanical-relay-input-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}