{"product_id":"yokogawa-saed5d-digital-signal-terminal-board","title":"Yokogawa SAED5D Digital Signal Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SAED5D\u003c\/strong\u003e is identified in supplier listings as a digital signal terminal board for the Field Input\/Output (FIO) subsystem of the CENTUM VP control system. It provides field wiring termination for digital I\/O modules through M4 screw terminals, with a 32-point connection arrangement. Its selection requires verification of the connected ADV-series module and the corresponding signal cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Board Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe terminal board provides the physical interface between field wiring and the digital I\/O module. It organizes field signal connections at the cabinet level and allows field conductors to be terminated using screw terminals rather than directly at the I\/O module connector.\u003c\/p\u003e\n\u003cp\u003eThe 32-point arrangement supports digital signal wiring for the associated ADV-series modules. The terminal board itself is a passive wiring interface; signal acquisition and output processing are handled by the connected I\/O module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSupported I\/O Modules and Cables\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available Yokogawa terminal-board specification identifies the following module and cable combinations:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Module\u003c\/th\u003e\n\u003cth\u003eConnection Cable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eAKB331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003eAKB331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV161\u003c\/td\u003e\n\u003ctd\u003eAKB337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV561\u003c\/td\u003e\n\u003ctd\u003eAKB337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFor ADV161 and ADV561 applications, \u003cstrong\u003etwo AED5D terminal boards or two AKB337 cables are required for one I\/O module set\u003c\/strong\u003e, according to the manufacturer's terminal-board specification. Confirm the actual hardware arrangement before ordering replacement parts.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAED5D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Signal Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e32 points x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eADV151, ADV551, ADV161, ADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Cables\u003c\/td\u003e\n\u003ctd\u003eAKB331, AKB337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 MOhm or greater at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnused connectors should retain their protective caps to prevent dust accumulation and protect connector pins. This is particularly relevant when maintaining spare terminal boards or replacing components in an existing FIO cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital signal points does the SAED5D support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified arrangement provides 32 points per terminal board set.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which connection cable should be used with the SAED5D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: AKB331 is specified for ADV151 and ADV551 modules, while AKB337 is specified for ADV161 and ADV561 modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SAED5D support dual-redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AED5D terminal-board specification covers single- and dual-redundant applications. For ADV161 and ADV561, two terminal boards or two AKB337 cables are required for one module set.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69452900630770,"sku":"SAED5D","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SAED5D2.jpg?v=1795422255","url":"https:\/\/www.petrospare.com\/products\/yokogawa-saed5d-digital-signal-terminal-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}