{"product_id":"yokogawa-nfsb100-500-sbt01-sb-bus-repeat-module","title":"Yokogawa NFSB100-500\/SBT01 SB Bus Repeat Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFSB100-500\/SBT01\u003c\/strong\u003e is an SB Bus Repeat Module designed for the FCN modular controller system. It connects a control unit to I\/O extension units, extending the SB bus for distributed I\/O expansion. The module supports redundant SB bus configurations and includes an SB bus T-joint under the \/SBT01 option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100 extends the FCN local SB bus between the control unit and its I\/O extension units. It uses serial communication at 128 Mbps, providing the communication path for data exchange between the controller and the connected expansion units.\u003c\/p\u003e\n\u003cp\u003eA single SB bus configuration uses one repeat module in the designated slot. For a duplexed SB bus, two repeat modules are installed in each applicable unit, with dedicated SB bus cables and T-joints connecting the communication paths.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports connection of up to \u003cstrong\u003e2 I\/O extension units\u003c\/strong\u003e, with a maximum of 3 units including the control unit.\u003c\/li\u003e\n\u003cli\u003eMaximum transmission distance is 8 m per SB bus line.\u003c\/li\u003e\n\u003cli\u003eSupports single and duplexed SB bus configurations.\u003c\/li\u003e\n\u003cli\u003eOccupies one module slot.\u003c\/li\u003e\n\u003cli\u003eUses dedicated NFCB301 SB bus cables for interconnection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe communication distance and extension-unit limit should be considered when planning the physical layout of an FCN controller installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eParameter | Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFSB100-500\/SBT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSB Bus Repeat Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable System\u003c\/td\u003e\n\u003ctd\u003eFCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Method\u003c\/td\u003e\n\u003ctd\u003eSerial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003e8 m per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Extension Units\u003c\/td\u003e\n\u003ctd\u003e2 (3 units including control unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle \/ Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Occupancy\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Slot\u003c\/td\u003e\n\u003ctd\u003eSlot 10 (single bus); Slots 9 and 10 (duplexed bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e32.8 x 130 x 142.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Option\u003c\/td\u003e\n\u003ctd\u003eSB bus T-joint (\/SBT01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front panel provides three green LEDs for checking hardware and communication activity:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSTATUS:\u003c\/strong\u003e Lights when the module hardware is operating normally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSND:\u003c\/strong\u003e Lights during transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCV:\u003c\/strong\u003e Lights during reception.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese indicators help maintenance personnel distinguish normal hardware status from active transmit and receive operations when checking the SB bus connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnection and Installation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100 is designed for installation on the applicable FCN base module. The manufacturer's documentation specifies the NFBU200 long base module for this SB bus repeat module; it cannot be installed on the N2BU051\/NFBU050 short base module or the N2BU030 compact base module.\u003c\/p\u003e\n\u003cp\u003eWhen connecting the control unit and extension units, the SB bus requires appropriate T-joints and dedicated cables. The bus termination arrangement must follow the manufacturer's specified configuration, including terminators at both ends of the SB bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the NFSB100-500\/SBT01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It extends the FCN controller's SB bus to connect I\/O extension units. It provides the serial communication link between the control unit and the expansion units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the NFSB100 support a redundant SB bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. A duplexed configuration requires two SB bus repeat modules in each applicable unit. The modules use separate SB bus communication paths connected through dedicated T-joints and cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is included in the \/SBT01 configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/SBT01 option specifies an SB bus T-joint supplied with the module. It is different from \/SBT02, which specifies a T-joint with a built-in terminator.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69352134017266,"sku":"NFSB100-500\/SBT01","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/NFSB100-500SBT012.jpg?v=1794815223","url":"https:\/\/www.petrospare.com\/products\/yokogawa-nfsb100-500-sbt01-sb-bus-repeat-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}