{"product_id":"yokogawa-nfcp100-s05-fcn-cpu-module","title":"Yokogawa NFCP100-S05 FCN CPU Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP100-S05\u003c\/strong\u003e, based on the \u003cstrong\u003eNFCP100\u003c\/strong\u003e FCN CPU module, executes real-time control programs and manages communication between the controller and its I\/O modules through the dual SB bus interface. It provides Ethernet connectivity, ECC-protected memory, serial communication and CPU duplexing capability for Yokogawa FCN autonomous controller systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccording to Yokogawa's official FCN-100 hardware documentation, the model designation is structured as follows:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNFCP100\u003c\/td\u003e\n\u003ctd\u003eFCN CPU module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eFixed suffix code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe NFCP100-S05 is the standard, non-explosion-protected CPU configuration. It should not be confused with the S06 version, which includes the ISA Standard G3 option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP100-S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSTARDOM FCN-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFCN CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eMMX-Pentium, 166 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic RAM\u003c\/td\u003e\n\u003ctd\u003e1 MB ECC, battery-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Card\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e2 ports, 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd\u003e10BASE-T \/ 100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232-C, 9-pin male D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Baud Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Interface\u003c\/td\u003e\n\u003ctd\u003eDuplex-capable SB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Calculated Power\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2700 mAh lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuplex Configuration\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65.8 x 132 x 145.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccupied Slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (FCN system installation condition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (FCN system installation condition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAS Functions\u003c\/td\u003e\n\u003ctd\u003eWatchdog timer, temperature monitoring and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eSpecifications are based on Yokogawa GS 34P02Q12-01E. The 9 W figure is calculated from the specified maximum 5 V supply current.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFCN CPU Architecture and Communication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFCP100-S05 executes real-time controller applications under an operating system supporting IEC 61131-3-compliant programming languages. It also supports Java virtual machine operation.\u003c\/p\u003e\n\u003cp\u003eIts communication architecture consists of two Ethernet ports and an SB bus interface:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e Two independent physical RJ45 interfaces support 10BASE-T and 100BASE-TX connections at 10\/100 Mbps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSB bus:\u003c\/strong\u003e Provides the local communication interface between the CPU and FCN I\/O modules. The bus supports duplex configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232-C:\u003c\/strong\u003e Provides asynchronous, full-duplex serial communication through a 9-pin male D-sub connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory protection:\u003c\/strong\u003e ECC is implemented in both the 128 MB main memory and 1 MB static RAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAS monitoring:\u003c\/strong\u003e Hardware diagnostics include watchdog and temperature monitoring functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CPU can operate in a duplex configuration. When CPU modules are configured redundantly, the RS-232-C serial port cannot be used. This restriction must be considered when assigning maintenance and communication interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFCP100-S05 support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Yokogawa specifies hot-swappable modules for the FCN-100 hardware platform. Replacement procedures must follow the system configuration and applicable maintenance instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the RS-232-C port remain operational in a redundant CPU configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The RS-232-C serial interface is unavailable when CPU modules operate in a duplex configuration. Ethernet should be considered for communication requirements in this arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum CPU power consumption?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified supply is 5 VDC +\/-5%, with a maximum current consumption of 1.8 A. The corresponding calculated maximum power is 9 W. Verify the available backplane power capacity before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eMounting:\u003c\/strong\u003e Install the CPU in the designated two-slot position of a compatible FCN base module. Verify the base module configuration before insertion.\u003c\/p\u003e\n\u003cp\u003e2. \u003cstrong\u003ePower supply:\u003c\/strong\u003e Confirm that the backplane provides the specified 5 VDC supply within the permitted voltage tolerance.\u003c\/p\u003e\n\u003cp\u003e3. \u003cstrong\u003eEthernet wiring:\u003c\/strong\u003e Connect the RJ45 interfaces using suitable industrial Ethernet cabling. Maintain separation from high-voltage and motor power cables.\u003c\/p\u003e\n\u003cp\u003e4. \u003cstrong\u003eSerial communication:\u003c\/strong\u003e Verify RS-232-C pin assignments and communication settings before connecting external equipment. Do not plan to use this interface in a duplex CPU configuration.\u003c\/p\u003e\n\u003cp\u003e5. \u003cstrong\u003eGrounding and shielding:\u003c\/strong\u003e Follow the Yokogawa system grounding instructions. Avoid uncontrolled shield connections that may introduce ground loops.\u003c\/p\u003e\n\u003cp\u003e6. \u003cstrong\u003eEnvironmental conditions:\u003c\/strong\u003e Maintain the FCN installation environment within the specified operating temperature and humidity limits. The published system conditions include 0 to 55 deg C and 5 to 95 %RH without condensation.\u003c\/p\u003e\n\u003cp\u003e7. \u003cstrong\u003eStartup verification:\u003c\/strong\u003e Check the HRDY, RDY and CTRL indicators for CPU hardware, system and control status. Check LINK and ACT indicators to verify Ethernet connectivity and traffic.\u003c\/p\u003e\n\u003cp\u003e8. \u003cstrong\u003eRedundant configuration:\u003c\/strong\u003e Confirm CPU model compatibility, duplex configuration and SB bus arrangement before commissioning.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69395913474290,"sku":"NFCP100-S05","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/NFCP100-S052.jpg?v=1795058103","url":"https:\/\/www.petrospare.com\/products\/yokogawa-nfcp100-s05-fcn-cpu-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}