{"product_id":"yokogawa-nfai835-s50-analog-i-o-module","title":"Yokogawa NFAI835-S50 Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFAI835-S50\u003c\/strong\u003e is an isolated analog I\/O module designed to handle 4-20 mA field signals. It provides four analog input channels and four analog output channels, with isolation between the field signals, system interface, and individual channels. The module supports bidirectional analog signal interfacing within the Yokogawa FCN I\/O platform.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFAI835-S50 combines analog input and output functions in one module. Its four input channels receive 4-20 mA signals from field instruments, while its four output channels provide 4-20 mA signals to external control devices.\u003c\/p\u003e\n\u003cp\u003eChannel isolation separates individual signal circuits and provides electrical isolation between the I\/O signals and the system. This arrangement is relevant when connecting multiple field circuits with different electrical reference potentials.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Performance and Signal Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input channels have an accuracy of \u003cstrong\u003e+\/-0.1% of full scale\u003c\/strong\u003e, while the output channels have an accuracy of \u003cstrong\u003e+\/-0.3% of full scale\u003c\/strong\u003e. Both input and output data have a 10 ms refresh cycle. The input and output step response times are 100 ms, providing the timing reference for signal acquisition and output updates.\u003c\/p\u003e\n\u003cp\u003eThe module provides 500 V AC withstand voltage for 1 minute between the I\/O signals and the system, and between individual channels. This electrical separation helps limit the transfer of electrical disturbances between field circuits and the controller interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Control and Field Signal Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach output channel supports a load resistance of 0 to 750 ohms. Circuit-open detection operates at 0.65 mA or less. The output fallback function can be configured by channel, with two available responses:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHOLD:\u003c\/strong\u003e Retains the output when fallback is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSETV:\u003c\/strong\u003e Outputs a specified value when fallback is detected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFallback detection takes 4 seconds. This setting determines how the output behaves when the module detects a fallback condition and should be considered when configuring connected control devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel and Suffix Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFAI835-S50 ordering code identifies the standard, basic version without explosion protection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFAI835:\u003c\/strong\u003e Analog I\/O Module with four isolated 4-20 mA input channels and four isolated 4-20 mA output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S:\u003c\/strong\u003e Standard type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e Without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0:\u003c\/strong\u003e Basic type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified configuration should not be confused with the -H HART communication version or the -E explosion-protected version.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAI835-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividual channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e250 ohms (power ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0-750 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit-Open Detection\u003c\/td\u003e\n\u003ctd\u003e0.65 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Cycle\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e20.2-29.3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Fallback\u003c\/td\u003e\n\u003ctd\u003eHOLD \/ SETV, configurable by channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFallback Detection Time\u003c\/td\u003e\n\u003ctd\u003e4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e360 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e450 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e107.5 x 130 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Connection Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module requires a 24 V DC supply to the analog field power supply terminal of the power supply module. The actual transmitter supply voltage available at the field connection is specified as 20.2 to 29.3 V, depending on the applied analog field supply voltage.\u003c\/p\u003e\n\u003cp\u003eExternal field wiring can use a pressure clamp terminal or MIL connector cable. When using a MIL connector cable, the applicable withstand voltage depends on the electrical specifications of the selected cable.\u003c\/p\u003e\n\u003cp\u003eThe module's power consumption must also be included in the FCN power supply capacity calculation. Check both the 5 V DC system supply and 24 V DC analog field supply requirements against the installed power supply module ratings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many analog signals can the NFAI835-S50 handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It handles four 4-20 mA input signals and four 4-20 mA output signals. Both signal groups have individual channel isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the output channels retain their values during a fallback condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The output fallback function supports HOLD to retain the output or SETV to apply a configured value. The response can be configured separately for each output channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFAI835-S50 support HART communication or explosion protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The -S50 configuration is the standard type without explosion protection. Yokogawa identifies -H as the HART communication option and -E as the explosion-protected option; these should not be assumed to be included in the -S50 version.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69399644012786,"sku":"NFAI835-S50","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/NFAI141-S012.jpg?v=1794195128","url":"https:\/\/www.petrospare.com\/products\/yokogawa-nfai835-s50-analog-i-o-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}