{"product_id":"yokogawa-nfaf135-s00-frequency-input-module","title":"Yokogawa NFAF135-S00 Frequency Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFAF135-S00\u003c\/strong\u003e is an 8-channel frequency input module for the STARDOM FCN control platform. It measures pulse signals from contact inputs and voltage pulse sources, converting pulse intervals into frequency values for controller processing. Its individually isolated input channels support frequency measurement from 0.1 Hz to 10 kHz, with a specified accuracy of 0.1% of reading.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAF135-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFrequency Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eContact ON\/OFF, voltage pulse (rectangular wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Input Pulse Width\u003c\/td\u003e\n\u003ctd\u003e40 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute, input-to-system and channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input Open Level\u003c\/td\u003e\n\u003ctd\u003e100 kOhm or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input Close Level\u003c\/td\u003e\n\u003ctd\u003e200 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Pulse High Level (VH)\u003c\/td\u003e\n\u003ctd\u003e3 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Pulse Low Level (VL)\u003c\/td\u003e\n\u003ctd\u003e-1 to 8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Pulse Swing (VH-VL)\u003c\/td\u003e\n\u003ctd\u003e3 V or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Pulse Source Resistance\u003c\/td\u003e\n\u003ctd\u003e1 kOhm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShunt Resistance\u003c\/td\u003e\n\u003ctd\u003eSelectable: OFF or 1000 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePull-up Resistance\u003c\/td\u003e\n\u003ctd\u003e68 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Cycle\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequency Measurement and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFAF135-S00 measures the time intervals between incoming pulses and calculates the corresponding frequency. The controller can use these frequency values to monitor rotational speed and other pulse-based process variables.\u003c\/p\u003e\n\u003cp\u003eThe module uses pulse-edge detection and interval measurement to calculate frequency. Its measurement method accumulates pulse counts and their time intervals to reduce the influence of clock resolution, particularly when measuring higher-frequency signals. At lower frequencies, the measurement update period can extend beyond the normal 10 ms cycle to accommodate longer pulse intervals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Signal Requirements and Power Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module accepts three basic signal configurations: open-collector contact pulses, relay contact pulses, and rectangular voltage pulses. The input connection and shunt resistance settings must match the selected signal type.\u003c\/p\u003e\n\u003cp\u003eFor contact inputs, the electrical capacity of the contact must meet the specified excitation requirements. Voltage pulse sources must provide a swing of at least 3 V, with a signal source resistance no greater than 1 kOhm.\u003c\/p\u003e\n\u003cp\u003eThe field power supply can be selected between 12 V DC and 24 V DC. The respective current limiter values are 40 mA and 30 mA. The FCN power supply module must receive 24 V DC at its analog field power supply terminal when the NFAF135 is installed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Mechanical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has a maximum current consumption of 300 mA at 5 V DC and 400 mA at 24 V DC. Its weight is 0.3 kg. External field connections are available through pressure-clamp terminals or a MIL connector cable, depending on the selected connection configuration.\u003c\/p\u003e\n\u003cp\u003eThe specified 500 V AC withstand voltage applies between input and system and between individual input channels. When using a MIL connector cable, the actual withstand voltage also depends on the cable's electrical specifications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NFAF135 product family is documented as a frequency input module with eight individually isolated channels. The supplied model reference is NFAF135-S00. The available manufacturer documentation describes the NFAF135 suffix and option coding, but does not establish a complete code-by-code interpretation of the exact -S00 designation. The full ordering configuration should therefore be checked against the product nameplate or original ordering record.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the NFAF135-S00 accept both contact and voltage pulse signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports open-collector contact pulses, relay contact pulses, and rectangular voltage pulses. The terminal connections and shunt resistance settings must be selected according to the input mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all eight channels measure frequencies up to 10 kHz?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified frequency range is 0.1 Hz to 10 kHz. However, open-collector dry-contact input has additional limitations: its maximum frequency is 800 Hz under the specified 1000 pF connection-capacity condition. Higher wiring and equipment capacitance further reduces the permitted frequency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply is required for field signal excitation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides selectable 12 V DC or 24 V DC field power. The current limiter values are 40 mA and 30 mA, respectively. The FCN power supply module must also supply 24 V DC to its analog field power supply terminal.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69399639752946,"sku":"NFAF135-S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/NFAF135-S501.jpg?v=1793930486","url":"https:\/\/www.petrospare.com\/products\/yokogawa-nfaf135-s00-frequency-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}