{"product_id":"yokogawa-f3yd64-1p-transistor-output-module","title":"Yokogawa F3YD64-1P Transistor Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3YD64-1P\u003c\/strong\u003e is a 64-point transistor output module designed to provide DC switching outputs for programmable controller systems. It supports a rated load voltage of 12 to 24 V DC, with 8 points per common line and photocoupler isolation between the external connection terminals and internal circuitry. The module also features a specified dielectric withstand voltage of 1500 V AC for one minute.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD64-1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTransistor Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Points\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Line Configuration\u003c\/td\u003e\n\u003ctd\u003e8 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e275 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e12 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Current\u003c\/td\u003e\n\u003ctd\u003e95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e2.89 x 8.32 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P provides 64 transistor output points, arranged in groups of 8 points per common line. This grouping is relevant when allocating output signals and planning the external load wiring. The common-line configuration should be considered when assigning field devices to output groups.\u003c\/p\u003e\n\u003cp\u003ePhotocoupler isolation separates the external output connection terminals from the module's internal circuitry. The specified withstand voltage is 1500 V AC for one minute between these two sections. This rating describes the isolation test condition and should not be interpreted as a continuous operating voltage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses a 5 V DC internal supply and has a specified current consumption of 275 mA. It also requires an external 12 to 24 V DC supply, with a specified current requirement of 95 mA. These are separate supply specifications and should be considered independently when checking the controller's power budget and field-side supply capacity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output signals can the F3YD64-1P control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 64 transistor output points. They are arranged in groups of 8 points per common line, which should be considered when planning output assignments and field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What external load voltage is supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The rated load voltage is 12 to 24 V DC, with an operating range of 10.2 to 26.4 V DC. The connected loads must operate within the specified voltage range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the F3YD64-1P provide electrical isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It uses photocoupler isolation between the external connection terminals and the internal circuit, with a specified withstand voltage of 1500 V AC for one minute.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Ratings and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P uses a \u003cstrong\u003esink-type transistor output configuration\u003c\/strong\u003e. Each point supports a maximum load current of 0.1 A, subject to a maximum of 0.4 A per common group. The maximum response time is 1 ms for both OFF-to-ON and ON-to-OFF transitions, making the module suitable for DC switching applications within its specified electrical limits.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates short-circuit and overheat protection. Its protection circuitry limits short-circuit current and can shut down an output if overheating occurs. An active clamp circuit provides surge protection. These protections are intended for short-term fault conditions, not continuous operation into a short circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExternal Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P uses two 40-pin connectors for external output connections. When connecting inductive loads such as relay coils, an additional surge protector or diode should be installed across the load, close to the device, to limit voltage transients at the module output terminals.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69369234292978,"sku":"F3YD64-1P","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/F3YD64-1P1_d0ddc818-df38-4978-b5a0-cd3c5323dfd9.jpg?v=1794898910","url":"https:\/\/www.petrospare.com\/products\/yokogawa-f3yd64-1p-transistor-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}