{"product_id":"yokogawa-asr133-s00-sr3s0-rtd-pot-input-module","title":"Yokogawa ASR133-S00\/SR3S0 RTD\/POT Input Module","description":"\u003cp\u003eThe Yokogawa ASR133-S00\/SR3S0 is an 8-channel RTD\/POT input module with a built-in barrier and isolated input circuits. It acquires resistance signals from resistance temperature detectors (RTDs) and potentiometers for processing by a Yokogawa control system. The specified configuration includes an ATSR3S-0 pressure clamp terminal connection for field wiring.\u003c\/p\u003e\n\u003ch3\u003eRTD and Potentiometer Signal Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe ASR133 accepts resistance-based field signals for temperature measurement and potentiometer position or resistance measurement. Its eight isolated input channels support the following sensor types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlatinum RTDs: Pt50, Pt100, Pt200, Pt500 and Pt1000.\u003c\/li\u003e\n\u003cli\u003eNickel RTDs: Ni100, Ni120 and Ni200.\u003c\/li\u003e\n\u003cli\u003ePotentiometers: 0 to 10 kOhm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRTD measurements use the resistance-temperature characteristics of the selected sensor to obtain temperature values. Potentiometer inputs provide resistance information that can represent the position of a connected measuring device. The supported sensor type and input configuration must be selected according to the field instrument.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Barrier and Input Isolation\u003c\/h3\u003e\n\u003cp\u003eThe built-in barrier separates the field-side measurement circuits from the system-side interface. This arrangement is intended for applications requiring isolated resistance-signal acquisition. The module's isolation and barrier characteristics should be considered when checking field wiring and hazardous-area installation requirements.\u003c\/p\u003e\n\u003ch3\u003eTerminal Connection\u003c\/h3\u003e\n\u003cp\u003eThe \/SR3S0 option identifies the pressure clamp terminal configuration associated with the ASR133 module. Yokogawa documentation identifies the corresponding terminal model as ATSR3S-0. The pressure clamp arrangement provides the field connection for the RTD and potentiometer input signals.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASR133-S00\/SR3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD\/POT Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrier\u003c\/td\u003e\n\u003ctd\u003eBuilt-in barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003ePt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotentiometer Input\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Model\u003c\/td\u003e\n\u003ctd\u003eATSR3S-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which RTD sensor types are supported by the ASR133-S00\/SR3S0?\u003c\/p\u003e\n\u003cp\u003eA: It supports five platinum RTD types (Pt50, Pt100, Pt200, Pt500 and Pt1000) and three nickel RTD types (Ni100, Ni120 and Ni200).\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the SR3S0 configuration?\u003c\/p\u003e\n\u003cp\u003eA: \/SR3S0 specifies the pressure clamp terminal option for RTD\/POT signal connections. The corresponding Yokogawa terminal model is ATSR3S-0.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module accept potentiometer signals?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports potentiometer inputs over a resistance range of 0 to 10 kOhm, in addition to the specified RTD sensor types.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69295030337778,"sku":"ASR133-S00\/SR3S0","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ASR133-S00SR3S0.jpg?v=1794450308","url":"https:\/\/www.petrospare.com\/products\/yokogawa-asr133-s00-sr3s0-rtd-pot-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}