{"product_id":"yokogawa-asi533-s00-ss3s0-analog-output-module","title":"Yokogawa ASI533-S00\/SS3S0 Analog Output Module","description":"\u003cp\u003eThe Yokogawa ASI533-S00\/SS3S0 is an eight-channel analog output module with a built-in barrier, designed to provide isolated 4-20 mA current signals to field devices. It forms part of Yokogawa's FIO analog I\/O hardware range. The module uses a pressure-clamp terminal connection and supports analog control signal transmission from the control system to field equipment.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ASI533 provides eight isolated analog output channels. Each channel delivers a 4-20 mA DC signal representing a control-system output value, allowing connected field devices to receive continuous control commands.\u003c\/p\u003e\n\u003cp\u003eTypical signal destinations include valve positioners and other current-input actuators. The built-in barrier provides the specified electrical interface for field circuits, with isolation between the control-side and field-side circuitry.\u003c\/p\u003e\n\u003ch3\u003eTerminal Connection\u003c\/h3\u003e\n\u003cp\u003eThe \/SS3S0 configuration is associated with the single pressure-clamp terminal arrangement for the analog output module. Yokogawa identifies the corresponding terminal model as ATSS3S-0.\u003c\/p\u003e\n\u003cp\u003eThe terminal arrangement should be checked when replacing an existing module. A dual-redundant terminal configuration uses a different terminal model, ATSS3D, and should not be assumed interchangeable with the single-terminal configuration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI533-S00\/SS3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module with Built-In Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0-750 ohm at 20 mA; 0-600 ohm at 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-48 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA (5 V DC); 350 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrier Type\u003c\/td\u003e\n\u003ctd\u003eIsolated interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eNot supported by standard S00 version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eATSS3S-0 pressure-clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Gas Resistance\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 x 107.5 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBuilt-In Barrier and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe built-in barrier separates the field interface electrically from the control system. The module is specified for installation in Zone 2 or Division 2 locations and connection to suitable field devices in Zone 0, Zone 1, or Division 1 areas, subject to the applicable explosion-protection certificates and installation conditions.\u003c\/p\u003e\n\u003cp\u003eThe isolation specification refers to the module interface. It should not be interpreted as independent galvanic isolation between all eight output channels. The manufacturer's documentation also identifies conditions under which multiple field-channel short circuits can affect intrinsic-safety protection.\u003c\/p\u003e\n\u003ch3\u003eOutput Performance and Load Conditions\u003c\/h3\u003e\n\u003cp\u003eThe 4-20 mA output range supports standard industrial current-loop control. The maximum output current is 23 mA, with the allowable load resistance decreasing from 750 ohm at 20 mA to 600 ohm at 23 mA.\u003c\/p\u003e\n\u003cp\u003eThe 10 ms data update period describes how frequently output data is refreshed, while the 100 ms step response time describes the module's response to a change in the commanded output. These are different performance parameters and should not be treated as interchangeable.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ASI533-S00\/SS3S0 support HART communication?\u003c\/p\u003e\n\u003cp\u003eA: No. The S00 version is the standard analog output configuration. Yokogawa identifies the HART-capable version with the H suffix, such as ASI533-H00.\u003c\/p\u003e\n\u003cp\u003eQ: Which terminal block is specified for ASI533-S00\/SS3S0?\u003c\/p\u003e\n\u003cp\u003eA: The specified single pressure-clamp terminal is ATSS3S-0. The dual-redundant terminal configuration uses ATSS3D-0 and has a different ordering designation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module drive a field device with a load resistance of 750 ohm?\u003c\/p\u003e\n\u003cp\u003eA: Yes, at an output current of 20 mA. At the maximum output current of 23 mA, the allowable load resistance is reduced to 600 ohm. The complete field-loop resistance must remain within the applicable limit.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69266162090226,"sku":"ASI533-S00\/SS3S0","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ASI533-S00SS3S02.jpg?v=1794281572","url":"https:\/\/www.petrospare.com\/products\/yokogawa-asi533-s00-ss3s0-analog-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}