{"product_id":"yokogawa-asd533-s00-sd3s0-digital-output-module","title":"Yokogawa ASD533-S00\/SD3S0 Digital Output Module","description":"\u003cp\u003eThe Yokogawa ASD533-S00\/SD3S0 is an 8-channel isolated digital output module with a built-in barrier. It provides discrete output signals for field-side interfaces, with an output response time of 10 ms and status output functionality. The specified \/SD3S0 ordering option identifies a pressure-clamp terminal block configuration for digital output, model ATSD3S-0.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ASD533 is designed for digital output applications requiring electrical isolation between the control system and field-side circuits. Its built-in barrier provides an isolated interface for connecting field devices under the specified electrical and intrinsic-safety conditions.\u003c\/p\u003e\n\u003cp\u003eThe module provides eight isolated output channels. Its output characteristics are specified as 12 V at 40 mA and 26 V at 0 mA, describing the output voltage under the corresponding load conditions rather than a fixed 24 V output rating.\u003c\/p\u003e\n\u003ch3\u003eOutput Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module provides a 10 ms output response time and a status output function. The specified withstand voltage is 1500 V AC. These characteristics are relevant when checking field-device requirements, output response expectations and electrical isolation conditions.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's documentation also specifies a maximum current consumption of 150 mA from 5 V DC and 500 mA from 24 V DC.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASD533-S00\/SD3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module with Built-In Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eASD533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e8, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e12 V at 40 mA; 26 V at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eStatus output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA (5 V DC); 500 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrier Type\u003c\/td\u003e\n\u003ctd\u003eIsolated interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Model\u003c\/td\u003e\n\u003ctd\u003eATSD3S-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Configuration\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering designation contains the module model, suffix codes and terminal block option:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eASD533\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module with Built-In Barrier, 8-channel, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/SD3S0\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal block for digital output, ATSD3S-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe \/SD3S0 option identifies the single pressure-clamp terminal block configuration. Yokogawa also lists \/SD3D0 for the dual-redundant pressure-clamp terminal block ATSD3D-0. These are distinct terminal connection configurations and should not be treated as interchangeable ordering codes without checking the installed hardware.\u003c\/p\u003e\n\u003ch3\u003eField Application Considerations\u003c\/h3\u003e\n\u003cp\u003eThe built-in barrier is intended for field interfaces requiring electrical isolation. When checking an existing installation or planning a replacement, verify the terminal block configuration and the electrical requirements of the connected field devices.\u003c\/p\u003e\n\u003cp\u003eYokogawa specifies that when short circuits occur in two or more field channels, all channels of the module fail to maintain intrinsic-safety protection. This limitation should be considered when reviewing field wiring and fault conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many digital output channels does the ASD533-S00 provide?\u003c\/p\u003e\n\u003cp\u003eA: It provides eight isolated digital output channels. The specified output characteristics are 12 V at 40 mA and 26 V at zero output current.\u003c\/p\u003e\n\u003cp\u003eQ: What does \/SD3S0 mean in the complete model number?\u003c\/p\u003e\n\u003cp\u003eA: It identifies the pressure-clamp terminal block option ATSD3S-0. The corresponding dual-redundant terminal block option is \/SD3D0, associated with ATSD3D-0.\u003c\/p\u003e\n\u003cp\u003eQ: What should be checked when replacing an existing ASD533 module?\u003c\/p\u003e\n\u003cp\u003eA: Verify the complete ASD533 model designation, terminal block type, field wiring and connected load requirements. Also check the applicable intrinsic-safety conditions before returning the module to service.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69295166095602,"sku":"ASD533-S00\/SD3S0","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ASD533-S00SD3S0.jpg?v=1794450989","url":"https:\/\/www.petrospare.com\/products\/yokogawa-asd533-s00-sd3s0-digital-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}