{"product_id":"yokogawa-asd143-p00-sb4s0-digital-input-module","title":"Yokogawa ASD143-P00\/SB4S0 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ASD143-P00\/SB4S0\u003c\/strong\u003e is a 16-channel digital input module with a built-in isolation barrier, designed for NAMUR-compatible field signal acquisition. It supports pulse counting and isolated status inputs. The complete order code specifies the pulse-count configuration and a pressure-clamp terminal block (ATSB4S-0) for field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ASD143 is designed to acquire discrete signals from NAMUR-compatible field devices in accordance with IEC 60947-5-6. Its 16 isolated input channels allow field status signals to be transferred to the control system while maintaining electrical isolation at the field interface.\u003c\/p\u003e\n\u003cp\u003eThe built-in barrier provides an isolated interface for field signal connections. This is relevant when interfacing with field devices in applications requiring intrinsic-safety protection; actual hazardous-area installation must follow the applicable certification and system control-drawing requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports status input and pushbutton input. For status acquisition, the specified response time is 15 ms. Pushbutton detection requires a minimum ON duration of 20 ms, while the maximum ON\/OFF cycle is 25 Hz.\u003c\/p\u003e\n\u003cp\u003eThe -P suffix identifies the pulse-count configuration. This allows the module to be selected for applications requiring pulse signal acquisition, subject to the specified input timing limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASD143-P00\/SB4S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module with Built-In Barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eNAMUR compatible, IEC 60947-5-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field interface and system; no channel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Input Response Time\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pushbutton ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5 V DC; 110 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrier Type\u003c\/td\u003e\n\u003ctd\u003eIsolated interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eATSB4S-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Classification\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Block and Model Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/SB4S0 option specifies the single pressure-clamp terminal block configuration for digital input connections. Yokogawa identifies the associated terminal block as \u003cstrong\u003eATSB4S-0\u003c\/strong\u003e. The corresponding dual-redundant terminal block is ATSB4D-0, ordered under the \/SB4D0 option.\u003c\/p\u003e\n\u003cp\u003eThe distinction is important when checking replacement parts and cabinet wiring. The terminal block configuration should match the installed hardware arrangement rather than being selected solely from the ASD143 base model.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous-Area Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe built-in barrier provides the electrical interface for connecting compatible field devices in intrinsically safe circuits. Yokogawa documentation identifies the module family for installation in Zone 2 or Division 2 locations, with connections to field devices in Zone 0, Zone 1 or Division 1 under the applicable certification conditions.\u003c\/p\u003e\n\u003cp\u003eThe module's isolation is between the field interface and the control system, not between individual input channels. Hazardous-area installation requires verification of the relevant ATEX or FM certification, entity parameters, associated equipment and special conditions of use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ASD143-P00\/SB4S0 support pulse counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Yokogawa defines the -P suffix as the pulse-count configuration. The specified maximum ON\/OFF cycle is 25 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal block is specified for ASD143-P00\/SB4S0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified terminal block is ATSB4S-0, a pressure-clamp terminal block for the single configuration. The dual-redundant option uses ATSB4D-0 and a different order-code suffix.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the 16 input channels individually isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module provides galvanic isolation between the field interface and the system, but Yokogawa explicitly states that there is no isolation between individual channels. This distinction should be considered when reviewing field wiring and intrinsic-safety arrangements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69350568657138,"sku":"ASD143-P00\/SB4S0","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ASD143-P00_SB4S0_1.jpg?v=1794798015","url":"https:\/\/www.petrospare.com\/products\/yokogawa-asd143-p00-sb4s0-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}