{"product_id":"yokogawa-arm55c-000-mechanical-relay-board","title":"Yokogawa ARM55C-000 Mechanical Relay Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ARM55C-000\u003c\/strong\u003e is a 32-point mechanical relay board designed for dry-contact output in the CENTUM VP Field Control Unit (FIO) subsystem. It provides selectable normally open (NO) or normally closed (NC) relay contacts, allowing digital output signals to be switched to field devices through mechanical relay contacts. The -000 ordering configuration identifies the 19-inch rack-mountable basic type.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eARM55C-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDry-contact relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003ea-contact (NO) or b-contact (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection Terminals\u003c\/td\u003e\n\u003ctd\u003eM3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Configuration\u003c\/td\u003e\n\u003ctd\u003e-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Contact Load\u003c\/td\u003e\n\u003ctd\u003e30 V DC, 1.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Contact Load\u003c\/td\u003e\n\u003ctd\u003e5 V, 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Current Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 0.85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 Mohm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (field terminals to case and 24 V terminals to field terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, KC, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ARM55C receives digital output signals from the ADV551 or ADV561 digital output module and switches the corresponding field circuits through mechanical relay contacts. Each of its 32 channels provides a dry-contact output, with the contact arrangement selectable as either an a-contact (normally open) or b-contact (normally closed).\u003c\/p\u003e\n\u003cp\u003eUnlike the ARM55D, which provides normally open contacts, the ARM55C supports both NO and NC contact configurations. This distinction is important when matching the relay board to the field device's required switching logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration and Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ARM55C is specified for the following CENTUM VP FIO digital output configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV551:\u003c\/strong\u003e 32-point digital output module with ATD5A terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV561:\u003c\/strong\u003e 64-point digital output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAKB331:\u003c\/strong\u003e Signal cable for 32-point configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAKB337:\u003c\/strong\u003e Signal cable for 64-point configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor one ADV561 installation, Yokogawa specifies two relay boards and two AKB337 signal cables. The relay board also supports single and dual-redundant digital I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Ratings and Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe maximum rated contact load is 30 V DC at 1.5 A per point. The minimum contact load is 5 V at 10 mA. These limits should be checked against the actual field-device voltage and current requirements before selecting the relay interface.\u003c\/p\u003e\n\u003cp\u003eThe internal relay circuit requires an external 24 V DC supply, with maximum current consumption of 0.85 A. This supply requirement is separate from the field-side load switched by the relay contacts.\u003c\/p\u003e\n\u003cp\u003eFor inductive loads, Yokogawa specifies a protection circuit connected in parallel with the load: an RC circuit for AC applications or a diode for DC applications. This suppresses switching noise generated by inductive loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ARM55C-000 ordering code is identified as follows:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eARM55C\u003c\/td\u003e\n\u003ctd\u003e32-point mechanical relay board with dry-contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe manufacturer also lists \/BR3 for a wall-mounting bracket and \/NTRY for a configuration without a cable tray. These are separate option codes and are not included in the ARM55C-000 designation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ARM55C-000 provide both normally open and normally closed outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each channel supports an a-contact (NO) or b-contact (NC) arrangement. The required contact type must be selected for the application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which digital output modules can connect to the ARM55C-000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified modules are ADV551 and ADV561. The corresponding signal cables are AKB331 for 32-point configurations and AKB337 for 64-point configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when connecting inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check that the field load does not exceed 30 V DC and 1.5 A per point. Install an appropriate protection circuit in parallel with inductive loads, using an RC circuit for AC or a diode for DC.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69395956826354,"sku":"ARM55C-000","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ARM55C-000.jpg?v=1795059167","url":"https:\/\/www.petrospare.com\/products\/yokogawa-arm55c-000-mechanical-relay-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}