{"product_id":"yokogawa-arm15a-000-mechanical-relay-input-board","title":"Yokogawa ARM15A-000 Mechanical Relay Input Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ARM15A-000\u003c\/strong\u003e is a 32-point mechanical relay board designed for dry-contact input interfacing in the FIO subsystem of the CENTUM VP control system. It connects field contact signals to digital input modules, with M4 screw terminals for field wiring. The board supports single and dual-redundant input configurations and uses an external 24 V DC supply for its internal circuitry and field-device circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eARM15A provides an interface between field dry contacts and the FIO digital input system. It receives contact signals from field devices and transfers their states through the associated relay and input circuitry to the digital input module.\u003c\/p\u003e\n\u003cp\u003eThe board provides 32 contact input points. Its specified ON and OFF resistance thresholds define the conditions under which a field contact is recognized as closed or open. This distinction is useful when checking contact wiring and input signal compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Interface and Module Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe documented FIO configurations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV151:\u003c\/strong\u003e 32-point digital input module used with an ATD5A terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV161:\u003c\/strong\u003e 64-point digital input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAKB331:\u003c\/strong\u003e Signal cable for the 32-point configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAKB337:\u003c\/strong\u003e Signal cable for the 64-point configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor an ADV161 configuration, two ARM15A relay boards and two AKB337 signal cables are required. The board supports single or dual-redundant digital input arrangements, subject to the selected system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Contact Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe internal circuit requires an external 24 V DC supply, with a maximum current consumption of 0.32 A. Field-device power is supplied through two separate lines, each serving 16 input points, with a maximum current of 0.3 A per line.\u003c\/p\u003e\n\u003cp\u003eThe contact input thresholds are ON at 150 ohms or less and OFF at 200 kohms or higher. These values define the documented contact-state recognition conditions; intermediate resistance values are not specified as valid ON or OFF states.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eARM15A-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMechanical Relay Contact Input Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDry-contact input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Signal\u003c\/td\u003e\n\u003ctd\u003e150 ohms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Signal\u003c\/td\u003e\n\u003ctd\u003e200 kohms or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Contact Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circuit Current\u003c\/td\u003e\n\u003ctd\u003eMax. 0.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Device Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, dual-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Supply Current\u003c\/td\u003e\n\u003ctd\u003eMax. 0.3 A per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eAt least 10 Mohms at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC between field terminals and case; 500 V AC between 24 V power terminals and case; 1.5 kV AC between power and field terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which digital input modules are documented for the ARM15A-000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented configurations include ADV151 with an ATD5A terminal block for 32-point input and ADV161 for 64-point input. The corresponding signal cable must also be selected according to the configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ARM15A-000 support dual-redundant input configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. ARM15A is specified for single or dual-redundant mechanical relay contact input configurations. The required board and cable quantities depend on the selected digital input module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply does the ARM15A-000 require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The internal circuitry requires an external 24 V DC supply, with a maximum current consumption of 0.32 A. Field-device power is supplied separately through two 24 V DC lines, each serving 16 points.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69351555563762,"sku":"ARM15A-000","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ARM15A-0002.jpg?v=1794809800","url":"https:\/\/www.petrospare.com\/products\/yokogawa-arm15a-000-mechanical-relay-input-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}