{"product_id":"yokogawa-anb11d-b25-bus-node-unit","title":"Yokogawa ANB11D-B25 Bus Node Unit","description":"\u003cp\u003eThe manufacturer identifies the ANB11D as a node unit for the dual-redundant ESB bus with optical repeater, designed for the CENTUM VP N-IO\/FIO architecture. The model code ANB11D-B25 identifies a specific power-supply and optical-repeater configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D-B25 collects and relays remote I\/O signals to a Field Control Unit (FCU) through the optical ESB bus. It supports the transmission of field analog signals and contact I\/O signals over optical communication links while supplying power to the installed I\/O modules and field transmitters.\u003c\/p\u003e\n\u003cp\u003eThe dual-redundant architecture uses redundant power supply modules and optical repeater slave modules. This configuration supports remote I\/O communication over a specified optical transmission distance of 5 km.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete model number identifies the following configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB11D\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus node unit with optical repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-B\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply, 5 km optical repeater configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe -B configuration is specified for use with ANT411-□E, ANT411-□F, or A2EN501-□□1 on the master side. The corresponding optical repeater slave modules are selected according to the specified 5 km configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB11D-B25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOptical ESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Repeater Distance\u003c\/td\u003e\n\u003ctd\u003e5 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Repeater Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screws\u003c\/td\u003e\n\u003ctd\u003e4 x M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Configuration and Signal Transmission\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D node unit accommodates several functional module types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Modules:\u003c\/strong\u003e Two power supply modules are used in the dual-redundant configuration. They supply power to the installed I\/O modules and field transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical ESB Bus Repeater Slave Modules:\u003c\/strong\u003e Two repeater modules support the redundant optical communication arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Modules:\u003c\/strong\u003e Up to eight I\/O modules can be installed, subject to the applicable module allocation and installation restrictions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe optical repeater configuration allows remote I\/O signals to be transmitted between the node unit and the FCU. The optical ESB bus provides the communication path for field signal data.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D-B25 is designed for 19-inch rack mounting using four M5 screws. An insulating bush is included as a standard accessory.\u003c\/p\u003e\n\u003cp\u003eFor safety and EMC compliance, Yokogawa specifies installation in a keyed metallic cabinet. I\/O module quantity and slot allocation must follow the applicable N-IO\/FIO system installation restrictions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ANB11D-B25 and ANB11D-D25?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both configurations use dual-redundant power supplies and 220-240 V AC input. The -B configuration supports the 5 km optical repeater arrangement, whereas -D specifies the 50 km configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which optical repeater master modules are compatible with ANB11D-B25?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented master-side configurations are ANT411-□E, ANT411-□F, and A2EN501-□□1. The corresponding optical repeater slave configuration must also be selected according to the 5 km arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does ANB11D-B25 include explosion protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The suffix code 5 identifies the basic type without explosion protection. Explosion-protected configurations use different suffix codes and must be selected according to the applicable hazardous-area requirements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69409371914482,"sku":"ANB11D-B25","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ANB11D-425BU2A.jpg?v=1792573114","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb11d-b25-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}