{"product_id":"yokogawa-anb11d-615-bu2a-optical-esb-bus-node-unit","title":"Yokogawa ANB11D-615\/BU2A Optical ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB11D-615\/BU2A\u003c\/strong\u003e is an Optical ESB Bus Node Unit designed for Yokogawa distributed control system I\/O architectures. It provides an interface between remote I\/O equipment and the Field Control Unit (FCU) through the optical ESB bus, supporting communication between distributed I\/O nodes and the controller. The unit belongs to the ANB11D dual-redundant ESB bus node platform.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D node collects and relays remote I\/O signals to the FCU. It converts field analog and contact I\/O signals into optical signals for transmission over the optical ESB bus. It also distributes power to the installed I\/O modules and associated transmitters.\u003c\/p\u003e\n\u003cp\u003eThe optical communication interface allows the I\/O node to be located remotely from the controller. The system architecture uses optical ESB repeater modules to establish the communication link between the FCU and remote node.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration and Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the ANB11D dual-redundant optical ESB node platform. The \/BU2A option is identified by Yokogawa as a connector unit for the ESB bus, without the additional terminator specified for \/BU2B.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB11D-615\/BU2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOptical ESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant Optical ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Fasteners\u003c\/td\u003e\n\u003ctd\u003e4 x M5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 221.5 x 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eESB Bus Communication and System Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D architecture uses optical ESB repeater modules to connect remote nodes with the FCU. Yokogawa identifies ANT502 and ANT512 as optical repeater slave modules for 5 km and 5 km to 50 km transmission configurations, respectively. The appropriate master and slave module combination depends on the selected node configuration.\u003c\/p\u003e\n\u003cp\u003eThe node can also be connected to an N-ESB Bus Module A2EN501 through the optical ESB bus. The actual connection arrangement and supported node count depend on the FCU platform and its installed software licenses.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and I\/O Module Arrangement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB11D platform supports power supply configurations of 100-120 V AC, 220-240 V AC, and 24 V DC. Its documented power consumption varies by supply configuration. The node also distributes power to the installed I\/O modules and field transmitters through its power supply modules.\u003c\/p\u003e\n\u003cp\u003eThe general specifications list a maximum of eight I\/O modules. Power supply modules and optical repeater slave modules are selected according to the required node configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe unit is designed for 19-inch rack mounting with four M5 mounting screws.\u003c\/li\u003e\n\u003cli\u003eYokogawa specifies installation in a keyed metallic cabinet to meet the applicable safety and EMC requirements.\u003c\/li\u003e\n\u003cli\u003eWhen I\/O modules with built-in barriers are installed, an insulating partition (T9083NA) is required.\u003c\/li\u003e\n\u003cli\u003eI\/O module quantity and allocation are subject to installation restrictions and cabinet temperature conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ANB11D and ANB11S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ANB11D is the dual-redundant ESB bus node configuration, whereas ANB11S is the single ESB bus node configuration. Their ordering codes and associated repeater configurations are different.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the \/BU2A option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: \/BU2A specifies a connector unit for the ESB bus. The \/BU2B version includes an ESB bus terminator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ANB11D connect directly to an FCU through optical fiber?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The optical connection requires the appropriate optical ESB repeater master and slave modules. The FCU-side configuration and repeater pairing must match the selected node variant and transmission distance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411253616882,"sku":"ANB11D-615\/BU2A","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ANB11D-425BU2A1.jpg?v=1792573114","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb11d-615-bu2a-optical-esb-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}