{"product_id":"yokogawa-anb10s-esb-bus-node-unit","title":"Yokogawa ANB10S ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10S\u003c\/strong\u003e is a Single ESB Bus Node Unit used in the CENTUM VP Field Control I\/O (FIO) system. It provides the communication interface between field I\/O modules and a Field Control Unit (FCU) through the ESB bus, while distributing power to the installed I\/O modules. Its configuration supports single or dual-redundant power supply arrangements, depending on the selected suffix code.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunction and System Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10S operates as a local node connected directly to an FCU through the ESB bus. It transfers analog and contact I\/O signals between the field-side modules and the control system. The node unit also provides the power distribution function required by the installed I\/O modules.\u003c\/p\u003e\n\u003cp\u003eIts hardware configuration accommodates power supply modules, ESB bus interface modules and I\/O modules. The single-bus designation distinguishes the ANB10S from the ANB10D, which is designed for a dual-redundant ESB bus configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Electrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe power supply is selected through the suffix codes. Available input options are 100-120 V AC, 220-240 V AC and 24 V DC. The specified electrical demand differs by supply type: AC configurations have separate apparent-power and active-power ratings, while the DC configuration is specified by input current.\u003c\/p\u003e\n\u003cp\u003eThe node unit can accommodate two power supply modules in a dual-redundant configuration. Supported power supply module models include PW481, PW482 and PW484. The power supply also provides power to field transmitters through the node unit's power distribution arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eESB Bus and I\/O Module Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10S connects to the FCU through an ESB Bus Coupler Module, EC401 or EC402. For a single configuration, the coupler is installed in slot 7, with slot 8 left empty. The node unit supports up to eight I\/O module positions, subject to the applicable system and module allocation restrictions.\u003c\/p\u003e\n\u003cp\u003eThe ESB bus interface uses SB401 slave modules. Two interface modules are used when the corresponding dual-redundant configuration is selected. The installed module combination must be checked against the FCU platform and the applicable FIO or N-IO system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel and Suffix Code Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code determines the power supply arrangement, input voltage and protection options. The following suffix selections are documented by Yokogawa for the ANB10S.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSingle ESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eN-IO \/ FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eSingle ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003e-3: Single; -4: Dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Supply Options\u003c\/td\u003e\n\u003ctd\u003e1: 100-120 V AC; 2: 220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Supply Option\u003c\/td\u003e\n\u003ctd\u003e4: 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Option\u003c\/td\u003e\n\u003ctd\u003e5: Basic, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Option\u003c\/td\u003e\n\u003ctd\u003eE: Basic, with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISA G3 Option\u003c\/td\u003e\n\u003ctd\u003e7: ISA Standard G3, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISA G3 Option\u003c\/td\u003e\n\u003ctd\u003eG: ISA Standard G3, with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Option\u003c\/td\u003e\n\u003ctd\u003e6: ISA Standard G3, -20 to 70 deg C, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Option\u003c\/td\u003e\n\u003ctd\u003eF: ISA Standard G3, -20 to 70 deg C, with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (100-120 V AC)\u003c\/td\u003e\n\u003ctd\u003e200 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (220-240 V AC)\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Supply Current\u003c\/td\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Module Positions\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable option codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\/CU1N: ESB Bus Connector Unit, part number S9562FA.\u003c\/li\u003e\n\u003cli\u003e\/CU1T: ESB Bus Connector Unit with terminator, part number S9564FA.\u003c\/li\u003e\n\u003cli\u003e\/ATDOC: Explosion Protection Manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \/ATDOC option is specified for configurations intended to comply with the ATEX Directive and UKEX Regulation. Explosion protection selection must be checked against the applicable installation requirements rather than inferred from the base model alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen installing FIO modules with built-in barriers, an insulating partition (part number T9083NA) must be fitted in the eighth slot. The number and allocation of I\/O modules are subject to installation restrictions, including cabinet and ambient-temperature conditions.\u003c\/p\u003e\n\u003cp\u003eThe connector unit, power supply configuration and protection suffix should be verified against the existing node arrangement before replacement. The ANB10S and ANB10D are not interchangeable descriptions: the former is for a single ESB bus, while the latter is designed for a dual-redundant ESB bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between Yokogawa ANB10S and ANB10D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ANB10S is a node unit for a single ESB bus, whereas the ANB10D is designed for a dual-redundant ESB bus. Their connector unit options also differ, so the complete model and connector configuration should be checked before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ANB10S use a dual-redundant power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -4 suffix specifies a dual-redundant power supply configuration. This arrangement uses two power supply modules. The -3 suffix specifies a single power supply configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which connector unit is required for the ANB10S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa specifies \/CU1N for the ESB Bus Connector Unit S9562FA and \/CU1T for the connector unit with terminator S9564FA. The required option depends on the bus connection and termination arrangement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69399893311730,"sku":"ANB10D-223","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/SNB10D-225CU2T1.jpg?v=1794897486","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb10s-esb-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}