{"product_id":"yokogawa-anb10d-427-cu2n-esb-bus-node-unit","title":"Yokogawa ANB10D-427\/CU2N ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-427\/CU2N\u003c\/strong\u003e is an ESB Bus Node Unit designed for dual-redundant Extended Serial Backboard (ESB) bus communication in Yokogawa CENTUM VP control systems. It provides the interface between field I\/O modules and the Field Control Unit (FCU), while distributing power to installed I\/O modules. This configuration includes dual-redundant power supplies, a 220-240 V AC input, ISA Standard G3 coating, and two ESB bus connector units.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D serves as a node-level interface between field I\/O modules and the FCU. It transfers analog and contact I\/O signals through the ESB bus, allowing the controller to exchange field data with the remote I\/O node.\u003c\/p\u003e\n\u003cp\u003eIn addition to bus communication, the unit distributes power to the installed I\/O modules and supports transmitter power supply through its power supply configuration. The dual-redundant architecture provides two power supply modules and two ESB bus interface slave modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete model number identifies the main hardware configuration and included bus connection accessories.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-427\/CU2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Coating\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNo explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Connector\u003c\/td\u003e\n\u003ctd\u003e2 x S9562FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003e8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003ctd\u003ePW482 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface Module\u003c\/td\u003e\n\u003ctd\u003eSB401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSuffix and Option Code Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code ANB10D-427\/CU2N identifies the following configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eTwo ESB bus connector units, part number S9562FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe \/CU2N option specifies two connector units for ESB bus connections. It differs from \/CU2T, which specifies two connector units with terminators (S9564FA). These options should not be treated as interchangeable when checking an existing system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Bus Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 220-240 V AC input operates at 50\/60 Hz. The dual-redundant power configuration uses two power supply modules, while two SB401 ESB Bus Interface Slave Modules provide the corresponding redundant bus interface arrangement.\u003c\/p\u003e\n\u003cp\u003eThe specified electrical consumption is 230 VA and 120 W. These values describe the node unit's electrical consumption and should not be confused with the total power capacity available to connected field devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and System Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D is designed for 19-inch rack mounting using four M5 mounting screws. When connecting the node unit to an FCU, the ESB Bus Coupler Module EC401 or EC402 is required.\u003c\/p\u003e\n\u003cp\u003eFor a dual-redundant FCU configuration, EC401 or EC402 modules must be installed in both slots 7 and 8. For a single ESB bus configuration, the coupler module is installed in slot 7, with slot 8 left empty.\u003c\/p\u003e\n\u003cp\u003eThe node unit supports up to eight I\/O modules. Actual module allocation and installation conditions must be checked against the applicable CENTUM VP FIO or N-IO system configuration requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ANB10D and ANB11D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ANB10D is a node unit for a dual-redundant ESB bus. ANB11D is designed for a dual-redundant ESB bus with an optical repeater. The two models have different node configurations and should be selected according to the required bus architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does ANB10D-427\/CU2N include ESB bus terminators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \/CU2N option specifies two standard ESB bus connector units, part number S9562FA. The \/CU2T option specifies two connector units with terminators, part number S9564FA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which ESB Bus Coupler Module is required to connect ANB10D to an FCU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa specifies EC401 or EC402 for this connection. Both slots 7 and 8 require coupler modules in a dual-redundant configuration. The required arrangement depends on the FCU bus configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69399934927090,"sku":"ANB10D-427\/CU2N","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ANB10D-425CU2N.jpg?v=1742471389","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb10d-427-cu2n-esb-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}