{"product_id":"yokogawa-anb10d-426-cu2n-ndel-dual-redundant-esb-bus-node-unit","title":"Yokogawa ANB10D-426\/CU2N\/NDEL Dual-Redundant ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-426\/CU2N\/NDEL\u003c\/strong\u003e is a dual-redundant ESB Bus Node Unit designed to connect Field Network I\/O (FIO) modules to the CENTUM VP control system. It features dual-redundant power supplies, a 220-240 V AC power configuration, ISA Standard G3 environmental protection, and an extended operating temperature option. The \/CU2N and \/NDEL options specify the ESB bus connector units and node expansion software license.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D provides the node interface between FIO modules and the dual-redundant ESB bus. It forms part of the distributed I\/O architecture, allowing field input and output signals to be exchanged with the Field Control Station (FCS) through the ESB communication network.\u003c\/p\u003e\n\u003cp\u003eThe dual-redundant configuration provides two power supply paths. This arrangement supports power continuity if one supply path becomes unavailable, subject to the installed power supply configuration and system conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Environmental Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe -426 suffix defines three configuration elements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e-4: Dual-redundant power supply.\u003c\/li\u003e\n\u003cli\u003e2: 220-240 V AC power supply, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e6: ISA Standard G3 option, -20 to 70 deg C temperature option, and no explosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe G3 option provides environmental protection against corrosive contaminants. The temperature option specifies an extended operating range. Yokogawa's ordering specifications state that this combined G3 and temperature configuration is selectable when the ANB10 unit is connected to an Optical ESB Bus Node Unit (ANB11). This installation condition should be checked during system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eESB Bus Interface and Connector Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/CU2N option supplies \u003cstrong\u003etwo S9562FA ESB Bus Connector Units\u003c\/strong\u003e for the dual-redundant bus configuration. This provides the physical connector hardware for the two ESB bus paths.\u003c\/p\u003e\n\u003cp\u003eThe \/NDEL option is the Software License for Node Expansion. Yokogawa specifies this option for connecting the node unit to the AFV10, AFV30, AFV40 and AFF50 Field Control Unit families in the applicable FIO configuration. It is a system-level licensing option rather than an additional communication module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D hardware configuration supports the following module arrangement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo PW481, PW482 or PW484 power supply modules for dual-redundant operation.\u003c\/li\u003e\n\u003cli\u003eTwo SB401 ESB Interface Slave Modules for dual-redundant communication.\u003c\/li\u003e\n\u003cli\u003eUp to eight I\/O modules, subject to system configuration and installation restrictions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe power supply modules provide power to the installed I\/O modules and field transmitters. The SB401 modules handle the ESB interface function. The actual I\/O module allocation depends on the connected Field Control Unit and the applicable system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-426\/CU2N\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Option\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Connector Option\u003c\/td\u003e\n\u003ctd\u003e\/CU2N, 2 x S9562FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Option\u003c\/td\u003e\n\u003ctd\u003e\/NDEL, Node Expansion License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Modules\u003c\/td\u003e\n\u003ctd\u003e2 x PW481, PW482 or PW484\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Interface Modules\u003c\/td\u003e\n\u003ctd\u003e2 x SB401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Modules\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screws\u003c\/td\u003e\n\u003ctd\u003e4 x M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 221.5 x 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and System Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D is designed for 19-inch rack mounting and uses four M5 mounting screws. When connecting the node unit to an applicable Field Control Unit, the ESB Bus Coupler Module EC401 or EC402 is required. For a dual configuration, the coupler modules occupy slots 7 and 8; for a single configuration, the coupler occupies slot 7 and slot 8 remains empty.\u003c\/p\u003e\n\u003cp\u003eWhen installing FIO modules with built-in barriers, an insulating partition (Part No. T9083NA) must be fitted in the eighth slot. I\/O module allocation and cabinet temperature restrictions must also be checked against the applicable system installation documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ANB10D-426\/CU2N\/NDEL support dual-redundant ESB communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ANB10D is designed for a dual-redundant ESB bus configuration and uses two SB401 ESB Interface Slave Modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is included with the \/CU2N option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/CU2N option specifies two S9562FA ESB Bus Connector Units. It is the connector configuration for the dual-redundant ANB10D node unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the -20 to 70 deg C temperature range applicable to every ANB10D configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The -6 suffix combines the ISA Standard G3 option with the extended temperature option and no explosion protection. Yokogawa specifies this combination for use when the ANB10 unit is connected to an ANB11 Optical ESB Bus Node Unit. The actual system connection must be verified before selection.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411670425842,"sku":"ANB10D-426\/CU2N\/NDEL","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ANB10D-410S2.jpg?v=1740560506","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb10d-426-cu2n-ndel-dual-redundant-esb-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}