{"product_id":"yokogawa-anb10d-417-cu2n-dual-redundant-esb-bus-node-unit","title":"Yokogawa ANB10D-417\/CU2N Dual-Redundant ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-417\/CU2N\u003c\/strong\u003e is a dual-redundant ESB Bus Node Unit designed to connect distributed I\/O nodes to a CENTUM VP control system. It provides the node-side interface for ESB Bus communication and supports redundant power supply and bus configurations. The \/CU2N option specifies the ESB Bus Connector Unit configuration supplied with the node unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunction and System Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D acts as an interface between field I\/O modules and the Field Control Unit (FCU). It transfers analog I\/O and contact I\/O signals through the ESB Bus. It also distributes power to installed I\/O modules and connected transmitters.\u003c\/p\u003e\n\u003cp\u003eThe dual-redundant configuration uses two ESB Bus Interface Slave Modules (SB401). The corresponding FCU must have ESB Bus Coupler Modules (EC401 or EC402) installed in both slots 7 and 8 for a redundant configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration and Ordering Code\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe model designation identifies the main hardware configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eANB10D\u003c\/strong\u003e: Node Unit for Dual-Redundant ESB Bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-4\u003c\/strong\u003e: Dual-redundant power supply configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e: 100-120 V AC power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7\u003c\/strong\u003e: ISA Standard G3 option without explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/CU2N\u003c\/strong\u003e: ESB Bus Connector Unit, supplied with two S9562FA connector units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe -417 suffix therefore specifies a 100-120 V AC version, not a 220-240 V AC version. The \/CU2N option is distinct from \/CU2T, which specifies connector units with terminators.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-417\/CU2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant ESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA, 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface Modules\u003c\/td\u003e\n\u003ctd\u003e2 x SB401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Modules\u003c\/td\u003e\n\u003ctd\u003e2 x PW481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Module Slots\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Unit\u003c\/td\u003e\n\u003ctd\u003e\/CU2N, 2 x S9562FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISA Environmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 221.5 x 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Module Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D uses two power supply modules for its dual-redundant configuration. The PW481 is the specified power supply module for the 100-120 V AC version. Each power supply module provides power to the node's I\/O modules and connected transmitters.\u003c\/p\u003e\n\u003cp\u003eTwo SB401 modules provide the redundant ESB Bus interface. This hardware arrangement maintains separate bus interface modules and power supply modules within the node configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ANB10D-417\/CU2N support a 220-240 V AC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The -417 suffix identifies the 100-120 V AC version. The 220-240 V AC version uses suffix -427. Check the complete model number before selecting replacement hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is included in the \/CU2N option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/CU2N option specifies two ESB Bus Connector Units, part number S9562FA. The alternative \/CU2T option specifies connector units with terminators (S9564FA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O modules can the ANB10D accommodate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The published specification lists a maximum of eight I\/O modules. Actual module quantity and slot allocation depend on the installed module types and system configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411418276082,"sku":"ANB10D-417\/CU2N","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ANB10D-445CU2NNDEL_2.jpg?v=1742968044","url":"https:\/\/www.petrospare.com\/products\/yokogawa-anb10d-417-cu2n-dual-redundant-esb-bus-node-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}