{"product_id":"yokogawa-afv30s-s31262-field-control-unit","title":"Yokogawa AFV30S-S31262 Field Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AFV30S-S31262\u003c\/strong\u003e is a 19-inch rack-mountable Field Control Unit (FCU) for the CENTUM VP FIO control system. It provides field control processing and Vnet\/IP communication between the control station and distributed I\/O node units. Its ordering configuration identifies dual-redundant Vnet\/IP communication, a single power supply, and a 220-240 V AC supply option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFV30S serves as the control processing unit of a Field Control Station (FCS). It manages control functions and communicates with field I\/O through the FIO architecture. Its Vnet\/IP interface provides a dual-redundant communication path between the FCU and the CENTUM VP control network.\u003c\/p\u003e\n\u003cp\u003eThe model is the single-power-supply configuration. The suffix code 3 specifies dual-redundant Vnet\/IP communication, but does not indicate redundant power or dual-redundant processor modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration and Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFV30S supports connections to ESB Bus Node Units (ANB10) and Optical ESB Bus Node Units (ANB11), with a maximum of 13 node units per FCU. ESB Bus Coupler Modules EC401 or EC402 are required for these connections.\u003c\/p\u003e\n\u003cp\u003eFor dual-redundant ESB bus arrangements, the coupler modules must be installed in both slots 7 and 8. A single ESB bus configuration uses slot 7, leaving slot 8 empty. Remote optical ESB connections require the appropriate optical repeater arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified power supply is 220-240 V AC at 50\/60 Hz, with a rated power consumption of 230 VA. The unit uses M4 screw terminals for power, grounding and READY contact connections. Network connections use UTP cable rated CAT5e or better to a Layer 2 switch.\u003c\/p\u003e\n\u003cp\u003eThe READY output provides normally closed (NC) and common (C) contacts. These contacts open when the FCU fails, allowing external equipment to monitor the controller's fault status. The contact rating is 30 V DC maximum and 0.3 A maximum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eParameter | Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFV30S-S31262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eField Control Unit (FCU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eFIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREADY Contact Output\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREADY Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, max. 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Connectable Node Units\u003c\/td\u003e\n\u003ctd\u003e13 per FCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Coupler\u003c\/td\u003e\n\u003ctd\u003eEC401 or EC402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Cable\u003c\/td\u003e\n\u003ctd\u003eUTP, CAT5e or better\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connection\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Connection\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 265.9 x 207 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup\u003c\/td\u003e\n\u003ctd\u003eBattery backup, max. 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Recharge Time\u003c\/td\u003e\n\u003ctd\u003eMin. 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering code identifies the following configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFV30S\u003c\/td\u003e\n\u003ctd\u003eField Control Unit for FIO, 19-inch rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type for CP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP, single power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eFixed code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eFixed code for CENTUM VP R6.01 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe -S configuration identifies the CP461 processor platform. Yokogawa discontinued new ordering of the AFV30S configuration with CP461 following the processor supply termination on October 19, 2019. Existing units remain identifiable by their original ordering codes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does AFV30S-S31262 have redundant power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The suffix code 3 specifies dual-redundant Vnet\/IP communication with a single power supply. It should not be confused with a dual-power configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which processor is specified for AFV30S-S31262?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This model specifies the CP461 processor type. CP461 replacement with CP471 must be performed by a Yokogawa-authorized service engineer, not by the user. The applicable CENTUM VP software version and ESB coupler style must also be checked.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can AFV30S-S31262 connect directly to FIO node units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ESB Bus Node Units and Optical ESB Bus Node Units require an EC401 or EC402 bus coupler arrangement. The required slot allocation depends on whether the ESB connection is single or dual redundant.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69399918182642,"sku":"AFV30S-S31262","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AFV30D-S41251-1.jpg?v=1756102394","url":"https:\/\/www.petrospare.com\/products\/yokogawa-afv30s-s31262-field-control-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}