{"product_id":"yokogawa-afg10d-duplexed-field-control-unit","title":"Yokogawa AFG10D Duplexed Field Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AFG10D\u003c\/strong\u003e is a Duplexed Field Control Unit (FCU) designed for Yokogawa distributed control systems using the V net and Remote I\/O (RIO) architecture. It performs control processing within the Field Control Station (FCS) and supports redundant communication interfaces. The unit provides 32 Mbyte of main memory and is designed for 19-inch rack mounting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFG10D serves as the processing unit of a Field Control Station. It executes control computations and manages communication between the control station and connected RIO nodes. Its duplexed configuration provides a redundant field control arrangement, distinguishing it from the single-unit AFG10S configuration.\u003c\/p\u003e\n\u003cp\u003eThe unit uses a VR5432 processor operating at 133 MHz. Its 32 Mbyte main memory stores the data required for control processing. Battery-backed memory protection maintains the main memory contents for up to 72 hours during a power failure, subject to the specified battery conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFG10D provides interfaces for both V net and RIO communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV net:\u003c\/strong\u003e Dual-redundant communication interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRIO bus:\u003c\/strong\u003e Dual-redundant or single interface configuration, depending on the specified hardware arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode capacity:\u003c\/strong\u003e Supports connection of up to 8 nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe V net interface supports communication within the control system, while the RIO bus connects the FCU to remote I\/O nodes. These interfaces form the communication paths between control processing and distributed field equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Memory Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFG10D supports AC or DC power supply configurations. The required power supply type is determined by the applicable suffix code. Its power consumption differs according to the selected input voltage.\u003c\/p\u003e\n\u003cp\u003eThe FCU also provides a status contact output for failure indication. The two-terminal normally closed contact arrangement opens when the FCU fails, allowing external monitoring equipment to detect the unit's failure status.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFG10D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eV net \/ RIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eVR5432\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Frequency\u003c\/td\u003e\n\u003ctd\u003e133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e32 Mbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eBattery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory Backup Time\u003c\/td\u003e\n\u003ctd\u003eMaximum 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Recharge Time\u003c\/td\u003e\n\u003ctd\u003eMinimum 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV net Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIO Bus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant or single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Connectable Nodes\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCU Status Contact Output\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, maximum 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Options\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC, 220-240 V AC, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (100-120 V AC)\u003c\/td\u003e\n\u003ctd\u003e400 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (220-240 V AC)\u003c\/td\u003e\n\u003ctd\u003e410 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (24 V DC)\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003e8 x M5 screws; insulation bush accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Connection Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFG10D is designed for installation in a 19-inch rack. The specified mounting arrangement uses eight M5 screws, with insulation bushes listed as accessories.\u003c\/p\u003e\n\u003cp\u003ePower supply, grounding and FCU status contact connections use M4 screw terminals. The selected power supply configuration must match the ordered unit. Before installation or replacement, verify the existing FCU power arrangement and RIO communication configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between Yokogawa AFG10D and AFG10S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both models are Field Control Units for V net and RIO systems. AFG10D is the duplexed version, while AFG10S is the non-duplexed version. Their power consumption and hardware configuration also differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How much memory does the AFG10D provide, and how long is it retained during a power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AFG10D provides 32 Mbyte of main memory. Battery backup maintains the memory contents for a maximum of 72 hours, and the specified minimum battery recharge time is 48 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which power supply configurations are available for the AFG10D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented power supply options are 100-120 V AC, 220-240 V AC and 24 V DC. The actual power supply configuration must be identified from the complete ordering code and unit nameplate.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411770499314,"sku":"AFG10D","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AFS30D-H41212.jpg?v=1794281434","url":"https:\/\/www.petrospare.com\/products\/yokogawa-afg10d-duplexed-field-control-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}