{"product_id":"yokogawa-aff50d-h41201-duplexed-field-control-unit","title":"Yokogawa AFF50D-H41201 Duplexed Field Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AFF50D-H41201\u003c\/strong\u003e is a duplexed Field Control Unit (FCU) for Yokogawa's Field Control Station (FCS). It executes process control functions and manages communication between the control station and field I\/O. The unit features a VR5432 processor, 32 MB of main memory, dual-redundant V net communication, and a dual-redundant ESB bus interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AFF50D-H41201 serves as the processing unit of an FCS. It executes configured control functions and coordinates data exchange with field I\/O through the communication interfaces. Its duplexed architecture provides redundant control and communication paths for the field control station.\u003c\/p\u003e\n\u003cp\u003eThe V net interface is dual-redundant. The ESB bus interface is also always dual-redundant on this specific model, rather than being selectable as a single or dual interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessor and Memory Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller uses a \u003cstrong\u003eVR5432 processor operating at 133 MHz\u003c\/strong\u003e and provides 32 MB of main memory. Battery-backed memory protection preserves the main memory contents for up to 72 hours following a power failure. The specified minimum battery recharge time is 48 hours.\u003c\/p\u003e\n\u003cp\u003eThis backup function protects stored control information during a power interruption; it should not be confused with the duplexed processor architecture or the unit's redundant communication interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Status Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FCU provides the following communication and diagnostic interfaces:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV net:\u003c\/strong\u003e Dual-redundant communication interface using 10BASE-2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB bus:\u003c\/strong\u003e Dual-redundant interface on the AFF50D-H41201.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCU status output:\u003c\/strong\u003e Two terminals, NC and C, for external status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCU status contacts open during an FCU failure. Their contact rating is 30 V DC maximum at 0.3 A, allowing the status circuit to be incorporated into an appropriately rated external monitoring or alarm circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe product specification identifies three supply voltage configurations across the AFF50D family: 100-120 V AC, 220-240 V AC, and 24 V DC. The corresponding power consumption figures are 200 VA, 230 VA, and 5.5 A, respectively.\u003c\/p\u003e\n\u003cp\u003eThe complete ordering code must be checked when identifying the installed power supply. The 220-240 V AC configuration is the relevant selection for the H41201 ordering variant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFF50D-H41201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAFF50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eVR5432, 133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eBattery-backed memory, maximum 72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Recharge Time\u003c\/td\u003e\n\u003ctd\u003eMinimum 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV net Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant, 10BASE-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCU Status Output\u003c\/td\u003e\n\u003ctd\u003e2 terminals (NC, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, maximum 0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Contact Behavior\u003c\/td\u003e\n\u003ctd\u003eContacts open during FCU failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe hardware specifications are based on the AFF50D product specification and the CENTUM system documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the compact duplexed FCU configuration. The documented suffix structure includes the following selections:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAFF50D\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit for V net and FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H\u003c\/td\u003e\n\u003ctd\u003eCompact type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant V net (10BASE-2) and dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eFixed code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe H41201 configuration therefore identifies the 220-240 V AC version. The complete model number should be retained when ordering or checking an existing installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between AFF50S and AFF50D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: AFF50S is the single FCU version, while AFF50D is the duplexed version. The AFF50D-H41201 provides a redundant control configuration with dual-redundant V net and ESB bus interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the FCU status contacts when the controller fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NC and C status contacts open during an FCU failure. The external monitoring circuit must be designed within the specified maximum contact rating of 30 V DC and 0.3 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long can the main memory be protected during a power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Battery backup provides main memory protection for up to 72 hours. The specified minimum battery recharge time is 48 hours.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69411739173106,"sku":"AFF50D-H41201","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AFF50D-H41101_7fe2a755-2e44-4aec-afdb-f460c3c8198b.jpg?v=1795159626","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aff50d-h41201-duplexed-field-control-unit","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}