{"product_id":"yokogawa-aed5d-01-digital-terminal-board","title":"Yokogawa AED5D-01 Digital Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AED5D-01\u003c\/strong\u003e is a digital terminal board designed for Yokogawa Field Control Unit (FIO) systems. It provides field wiring termination for digital I\/O signals and supports both single and dual-redundant configurations. The board accommodates 32 digital signal channels and interfaces with compatible digital I\/O modules through dedicated connection cables.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAED5D-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSingle or dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable I\/O Modules\u003c\/td\u003e\n\u003ctd\u003eADV151, ADV551, ADV161, ADV561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Cable\u003c\/td\u003e\n\u003ctd\u003eAKB331 \/ AKB337, depending on I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital Signal Termination\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AED5D-01 provides the field wiring termination point for digital input and output signals. It connects field-side wiring to the corresponding FIO digital I\/O module, organizing signal connections between field devices and the control system.\u003c\/p\u003e\n\u003cp\u003eIts 32-channel arrangement supports high-density digital signal termination. The M4 screw terminals provide individual wiring connection points for field circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Module Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AED5D-01 is specified for use with the following Yokogawa digital I\/O modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV151:\u003c\/strong\u003e 32-channel, 24 V DC isolated digital input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV551:\u003c\/strong\u003e 32-channel, 24 V DC isolated digital output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV161:\u003c\/strong\u003e 64-channel, 24 V DC isolated digital input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV561:\u003c\/strong\u003e 64-channel, 24 V DC isolated digital output module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor ADV151 and ADV551, the terminal board uses the AKB331 connection cable. ADV161 and ADV561 require two sets of AED5D terminal boards and AKB337 cables to accommodate their 64-channel configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AED5D terminal board documentation identifies the following configuration options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBasic type.\u003c\/li\u003e\n\u003cli\u003eISA Standard G3 option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e-01\u003c\/strong\u003e ordering designation corresponds to the ISA Standard G3 option in the documented ordering convention. Confirm the complete suffix and hardware revision when selecting a replacement board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e When the AED5D is used in voltage output mode, it does not conform to the Non-Incendive standard. This restriction should be considered when evaluating the applicable installation and hazardous-area requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital channels does the AED5D-01 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AED5D terminal board provides 32 channels. Applications using the 64-channel ADV161 or ADV561 modules require two AED5D boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AED5D-01 be used with both digital input and output modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The documented module combinations include the ADV151 digital input module and ADV551 digital output module, as well as the 64-channel ADV161 and ADV561 modules with two terminal boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked before replacing an AED5D-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the connected I\/O module, channel configuration, connection cable and ISA Standard G3 option. Also check the voltage-output operating condition if Non-Incendive requirements apply.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69311454314738,"sku":"AED5D-01","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/AED5D-012.jpg?v=1794541052","url":"https:\/\/www.petrospare.com\/products\/yokogawa-aed5d-01-digital-terminal-board","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}