{"product_id":"yokogawa-adv551-p63-d5a00-digital-output-module","title":"Yokogawa ADV551-P63\/D5A00 Digital Output Module","description":"\u003cp\u003eThe Yokogawa ADV551-P63\/D5A00 is a 32-channel, 24 V DC isolated Digital Output Module designed to provide discrete control signals to external devices. It supports current-sink output operation and pulse width\/time-proportional output functions. This configuration includes status indication, ISA Standard G3 and extended temperature options, together with a KS Cable Interface Adapter (ATD5A-00).\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P63\/D5A00 converts digital control commands from the control system into electrical output signals for connected field circuits. Its 32 output channels support individual discrete control, while the current-sink configuration allows the module to switch connected loads by providing a path to the common negative side.\u003c\/p\u003e\n\u003cp\u003eThe -P suffix adds pulse width output and time-proportional output functions. These functions allow the control system to represent a time-based control demand through the ON\/OFF duration of an output signal, rather than relying only on steady-state discrete switching.\u003c\/p\u003e\n\u003ch3\u003eOutput Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module operates with a rated applied voltage of 24 V DC and supports a maximum load current of 100 mA per channel at 26.4 V. The actual load must remain within the specified channel current limit and voltage conditions.\u003c\/p\u003e\n\u003cp\u003eThe common negative (-) side is arranged in groups of 16 channels. This grouping is relevant when planning field wiring and connecting external loads, particularly where channel commons and isolation boundaries must be considered.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\/channel at 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Signal to System)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC, 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e500 V AC, 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Arrangement\u003c\/td\u003e\n\u003ctd\u003eCommon negative (-) side every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Option\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface Adapter\u003c\/td\u003e\n\u003ctd\u003eATD5A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModel Configuration and Ordering Information\u003c\/h3\u003e\n\u003cp\u003eThe complete ordering number identifies the following configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003e32-channel, 24 V DC Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003ePulse width output and time-proportional output functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eWith status display; without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option and -20 to 70 deg C temperature option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eKS Cable Interface Adapter for 32-channel digital signals, model ATD5A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe \/D5A00 option identifies the cable interface arrangement supplied for this configuration. It should be distinguished from pressure-clamp terminal block options such as ATD5S-00, which have different connection arrangements.\u003c\/p\u003e\n\u003ch3\u003ePulse Width and Time-Proportional Output\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 supports three output assignment patterns: status output, pulse width or time-proportional output, and mixed status\/pulse\/time-proportional output. These functions allow the module to handle conventional ON\/OFF commands as well as time-based output signals.\u003c\/p\u003e\n\u003cp\u003eFor pulse width output, two consecutive channel terminals are required, with the first terminal being an odd-numbered channel. When pulse width and time-proportional outputs are combined, the terminal assignment must follow the manufacturer's channel configuration rules.\u003c\/p\u003e\n\u003ch3\u003eElectrical Isolation and Field Wiring\u003c\/h3\u003e\n\u003cp\u003eThe module provides electrical withstand capability between output signals and the system, as well as between channel commons. Its 16-channel common grouping means that the 32 outputs are arranged into two common groups.\u003c\/p\u003e\n\u003cp\u003eWhen connecting DC relay loads, Yokogawa specifies the use of a spark killer diode. The external load and wiring must also remain within the rated voltage and current limits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV551-P63\/D5A00 support pulse width output?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -P suffix identifies the pulse width and time-proportional output functions. Pulse width output requires two consecutive terminals, starting with an odd-numbered terminal.\u003c\/p\u003e\n\u003cp\u003eQ: What cable interface is specified for the ADV551-P63\/D5A00?\u003c\/p\u003e\n\u003cp\u003eA: This configuration specifies the KS Cable Interface Adapter ATD5A-00 through option code \/D5A00. The adapter is intended for the 32-channel digital connection arrangement.\u003c\/p\u003e\n\u003cp\u003eQ: Is the ADV551-P63\/D5A00 suitable for operation without explosion protection?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Suffix code 6 specifies the version with status display and without explosion protection. It should not be confused with the explosion-protected suffix configurations.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69266130174194,"sku":"ADV551-P63\/D5A00","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV551-P63D5A00.jpg?v=1794281232","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv551-p63-d5a00-digital-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}