{"product_id":"yokogawa-adv551-p50-d5s00-digital-output-module","title":"Yokogawa ADV551-P50\/D5S00 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV551-P50\/D5S00\u003c\/strong\u003e is a 32-channel digital output module for the CENTUM VP FIO system. It provides isolated 24 V DC transistor outputs for transmitting ON\/OFF control signals to external field devices. This configuration includes the ATD5S-00 pressure clamp terminal block for field wiring and the pushbutton input function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\/D5S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Terminal Type\u003c\/td\u003e\n\u003ctd\u003ePressure Clamp Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Model\u003c\/td\u003e\n\u003ctd\u003eATD5S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Function\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eWithout status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eWithout explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Type\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Function and Signal Handling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 is designed to convert controller commands into discrete electrical output signals. Its 32 channels provide individual ON\/OFF control points for field-side devices. The 24 V DC output arrangement supports discrete control applications where external equipment responds to switching signals.\u003c\/p\u003e\n\u003cp\u003eThe module's electrical isolation separates the output signal circuits from the system side. This isolation helps limit the transfer of electrical disturbances between field wiring and the control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 uses a current-sink transistor output format. Each channel can handle a maximum load current of 100 mA at up to 26.4 V DC. The maximum output ON voltage is 2 V DC, while the maximum leakage current in the OFF state is 0.1 mA.\u003c\/p\u003e\n\u003cp\u003eThe external supply operates within a range of 20.4 to 26.4 V DC. The rated applied voltage is 24 V DC, which should be considered when checking the field load and power supply arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePulse Width and Time-Proportioning Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e-P suffix\u003c\/strong\u003e specifies pulse width output and time-proportioning ON\/OFF output functions. These functions allow the module to provide timed switching signals rather than only maintaining a steady ON or OFF state.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePulse width range: 8 ms to 7200 s.\u003c\/li\u003e\n\u003cli\u003ePulse width resolution: 8 ms.\u003c\/li\u003e\n\u003cli\u003eAdditional ON\/OFF delay: Maximum 1 ms.\u003c\/li\u003e\n\u003cli\u003eOutput response time: 3 ms or less for status output; 10 ms or less for mixed status and pulse outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe time-proportioning function supports control strategies that require repeated ON\/OFF switching over defined time intervals. Pulse width output uses two consecutive terminals, with the first terminal assigned an odd number.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Block and Field Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/D5S00 option specifies the \u003cstrong\u003eATD5S-00 pressure clamp terminal block\u003c\/strong\u003e for digital output connections. It provides the field wiring interface for the module without requiring the separate KS cable interface adapter.\u003c\/p\u003e\n\u003cp\u003eThe terminal configuration should be checked against the installed output assignment and field wiring diagram. When driving a DC relay, Yokogawa specifies connecting a diode to the load circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the ADV551-P50\/D5S00 a digital input or digital output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is a 32-channel digital output module. It sends transistor-based ON\/OFF signals to external field devices using a 24 V DC output arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the -P suffix and the 5 suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The -P suffix identifies the pulse width and time-proportioning output functions. The 5 suffix identifies the version without a status display and without explosion protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal block is supplied with the \/D5S00 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified terminal block is the Yokogawa ATD5S-00 pressure clamp terminal block for digital output wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Current\u003c\/td\u003e\n\u003ctd\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (signal to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Dimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 x 130 x 107.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe output isolation withstands 2 kV AC for 1 minute between the output signal and system. The specified isolation test condition is relevant when evaluating electrical separation between field circuits and the control system.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69311350997234,"sku":"ADV551-P50\/D5S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV551-P50D5S002.jpg?v=1794540747","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv551-p50-d5s00-digital-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}