{"product_id":"yokogawa-adv551-p50-d5d00-digital-output-module","title":"Yokogawa ADV551-P50\/D5D00 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV551-P50\/D5D00\u003c\/strong\u003e is a 32-channel, 24 V DC isolated digital output module for the CENTUM VP FIO system. It provides discrete transistor output signals for controlling external field devices. This configuration includes the pulse width output function and a dual pressure clamp terminal block (ATD5D-00), providing a defined interface for field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 converts digital output commands from the control system into discrete electrical signals for external loads. Its 32 isolated output channels support individual control signals, allowing the controller to operate connected devices according to the configured control logic.\u003c\/p\u003e\n\u003cp\u003eThe module supports pulse width output and time-proportional output functions. These functions allow digital switching signals to represent a variable control demand through changes in pulse duration or duty cycle, where supported by the application configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Block Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/D5D00 option identifies the dual pressure clamp terminal block configuration, associated with Yokogawa model \u003cstrong\u003eATD5D-00\u003c\/strong\u003e. This is the specified field wiring interface for the supplied module configuration.\u003c\/p\u003e\n\u003cp\u003eThe terminal block option should be checked against the installed cable and field wiring arrangement when replacing an existing module. The \/D5D00 version should not be confused with \/D5S00, which specifies a standard pressure clamp terminal block.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\/D5D00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\/channel at 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output ON Voltage\u003c\/td\u003e\n\u003ctd\u003e2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms or less (status output); 10 ms or less (mixed status and pulse outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 V DC; 60 mA from external power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (output signal to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDual pressure clamp terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Model\u003c\/td\u003e\n\u003ctd\u003eATD5D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107.5 x 32.8 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Characteristics and Signal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 uses current-sink transistor outputs. The field-side external supply provides the operating voltage for connected loads, while the module controls their switching states. The specified maximum load current is 100 mA per channel at 26.4 V DC.\u003c\/p\u003e\n\u003cp\u003eThe module supports three output functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Output (SO):\u003c\/strong\u003e Provides conventional ON\/OFF switching signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Width Output (PW):\u003c\/strong\u003e Generates one-shot pulses with a configurable pulse width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-Proportioning Output (TP):\u003c\/strong\u003e Controls ON\/OFF duration according to a time-proportioning demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor pulse width output, two consecutive terminals are assigned to one pulse output, with the first terminal required to have an odd number. This terminal allocation must be considered when configuring the module and planning field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuffix and Ordering Code Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003e32-channel, 24 V DC isolated digital output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003ePulse width output and time-proportional output functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5D00\u003c\/td\u003e\n\u003ctd\u003eDual pressure clamp terminal block, model ATD5D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe complete ordering number identifies the module together with its functional and terminal configuration. In particular, the \/D5D00 option distinguishes this version from standard pressure clamp terminal block configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ADV551-P50\/D5D00 and ADV551-P50\/D5S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Both use the ADV551 digital output module, but their terminal block configurations differ. The \/D5D00 version specifies a dual pressure clamp terminal block (ATD5D-00), whereas \/D5S00 specifies a pressure clamp terminal block (ATD5S-00).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ADV551-P50\/D5D00 generate pulse width output signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -P suffix identifies pulse width and time-proportional output functionality. Pulse width output supports a range of 8 ms to 7200 s, with an 8 ms resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the 32-channel configuration, 24 V DC field supply, current-sink output requirements, load current, and ATD5D-00 terminal block arrangement. Also check the configured output modes and terminal assignments, particularly where pulse width outputs are used.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69311182897394,"sku":"ADV551-P50\/D5D00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV551-P50_2.jpg?v=1740560381","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv551-p50-d5d00-digital-output-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}