{"product_id":"yokogawa-adv151-p50-d5a00-digital-input-module","title":"Yokogawa ADV151-P50\/D5A00 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P50\/D5A00\u003c\/strong\u003e is a 32-channel digital input module designed to receive 24 V DC discrete signals from external field devices. It supports both sink and source input configurations, with defined ON\/OFF voltage thresholds and an input response time of 8 ms or less for status input. This configuration includes a KS Cable Interface Adapter for 32-channel digital input connections (ATD5A-00).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P50\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20% per channel at rated input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (for status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Input Signal to System)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Configuration\u003c\/td\u003e\n\u003ctd\u003eOne common per 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, dedicated cable (AKB331), MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface Adapter\u003c\/td\u003e\n\u003ctd\u003eATD5A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital Input Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-P50\/D5A00 receives discrete voltage signals from external devices and converts their electrical states into digital input information for the control system. Its 32 input channels allow multiple field signals to be monitored through one module.\u003c\/p\u003e\n\u003cp\u003eThe module supports both sink and source input configurations. The ON-state voltage range is 18 to 26.4 V DC, while an input voltage of 5.0 V DC or less is recognized as OFF. These thresholds provide defined electrical conditions for field signal recognition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Protection and Electrical Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module specifies a withstand voltage of 2 kV AC for one minute between the input signal and the system. The withstand voltage between commons is 500 V AC for one minute, with a separate common for each group of 16 channels.\u003c\/p\u003e\n\u003cp\u003eThe maximum allowable input voltage is 30.0 V DC. Field signal voltages must remain within this limit to avoid exceeding the specified input rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnection and Cable Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-P50\/D5A00 supports several external connection methods:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure clamp terminal connection.\u003c\/li\u003e\n\u003cli\u003eDedicated cable connection using AKB331.\u003c\/li\u003e\n\u003cli\u003eMIL connector cable connection.\u003c\/li\u003e\n\u003cli\u003eKS Cable Interface Adapter ATD5A-00 for 32-channel digital input connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \/D5A00 option identifies the configuration supplied with the KS Cable Interface Adapter, model ATD5A-00. This adapter should be considered when checking the field wiring arrangement and replacement configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Suffix and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied ordering information identifies the following configuration details:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter for 32-channel digital input, model ATD5A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThese configuration details are relevant when matching the module against an existing installation. In particular, the pushbutton input option, status display configuration, and cable interface adapter should be checked before ordering a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital input channels does the ADV151-P50\/D5A00 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 32 digital input channels, operating with a rated input voltage of 24 V DC. The input configuration supports both sink and source arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the \/D5A00 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/D5A00 option specifies the KS Cable Interface Adapter for 32-channel digital input connections, model ATD5A-00. It should be included in configuration checks when replacing an existing unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the electrical isolation ratings of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified withstand voltage is 2 kV AC for one minute between input signal and system, and 500 V AC for one minute between commons. The commons are arranged in groups of 16 channels.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69307981889778,"sku":"ADV151-P50\/D5A00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV151-P50D5A002.jpg?v=1794536433","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv151-p50-d5a00-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}