{"product_id":"yokogawa-adv151-p50-b5s00-digital-input-module","title":"Yokogawa ADV151-P50\/B5S00 Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P50\/B5S00\u003c\/strong\u003e is a 32-channel digital input module designed to receive 24 V DC discrete signals in a Yokogawa control system. It belongs to the ADV151 digital input module family and is specified with isolated input channels, pushbutton input functionality, and a pressure clamp terminal block (ATB5S-00). The supplied configuration also specifies no status display and no explosion protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital Input Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module receives field ON\/OFF signals and converts their electrical states into digital input information for the control system. Its 32 isolated input channels support 24 V DC sink\/source signals. The isolation design provides electrical separation between field input signals and the system, as well as between channel groups.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e-P suffix\u003c\/strong\u003e identifies the pushbutton input function. In addition to detecting normal ON\/OFF status, this configuration supports pushbutton edge counting. This allows the control system to register discrete button operations rather than relying only on the maintained signal state.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input voltage thresholds define how field signals are interpreted:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput ON voltage: 18 to 26.4 V DC.\u003c\/li\u003e\n\u003cli\u003eInput OFF voltage: 5.0 V DC or less.\u003c\/li\u003e\n\u003cli\u003eInput current: 4.1 mA +\/-20% per channel at rated voltage.\u003c\/li\u003e\n\u003cli\u003eMaximum allowable input voltage: 30.0 V DC.\u003c\/li\u003e\n\u003cli\u003eInput response time: 8 ms or less for status input.\u003c\/li\u003e\n\u003cli\u003eMinimum ON detection time: 20 ms for pushbutton input.\u003c\/li\u003e\n\u003cli\u003eMaximum ON\/OFF cycle: 25 Hz for pushbutton input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe separation between the ON and OFF voltage thresholds provides a defined switching region. Field signals should remain within the specified input limits to ensure correct state detection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \/B5S00 option specifies the \u003cstrong\u003eATB5S-00 pressure clamp terminal block\u003c\/strong\u003e for digital input connections. This configuration provides the field wiring interface for the module and distinguishes it from versions ordered with dedicated cable or other terminal arrangements.\u003c\/p\u003e\n\u003cp\u003eThe module has common connections for every 16 channels. All 24 V DC input signals connected to the module must use the same polarity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel and Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003e32-channel, 24 V DC isolated digital input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/B5S00\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block for digital input, ATB5S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe complete ordering number \u003cstrong\u003eADV151-P50\/B5S00\u003c\/strong\u003e identifies the module and its specified terminal configuration. The \/B5S00 option should be checked when replacing an existing module because the terminal connection arrangement is part of the ordered configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P50\/B5S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eDC ON\/OFF, sink\/source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms (pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz (pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Function\u003c\/td\u003e\n\u003ctd\u003eEdge counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC, 1 minute (input signal to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Group Isolation Test\u003c\/td\u003e\n\u003ctd\u003e500 V AC, 1 minute (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eATB5S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between ADV151-P50\/B5S00 and a standard ADV151 digital input module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This ordering configuration includes the pushbutton input function, no status display, no explosion protection, and the ATB5S-00 pressure clamp terminal block. The complete suffix and option code should be checked when selecting a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can ADV151-P50\/B5S00 detect momentary pushbutton operations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The -P configuration supports pushbutton edge counting. The specified minimum ON detection time is 20 ms, with a maximum ON\/OFF cycle of 25 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when connecting 24 V DC field signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify that the input voltage meets the specified ON\/OFF thresholds and does not exceed 30.0 V DC. The module uses a common connection for every 16 channels, and all connected input signals must have the same polarity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":69307923759346,"sku":"ADV151-P50\/B5S00","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/5589\/5794\/files\/ADV151-P50B5S002.jpg?v=1794536101","url":"https:\/\/www.petrospare.com\/products\/yokogawa-adv151-p50-b5s00-digital-input-module","provider":"Petro Spare Industrial Limited","version":"1.0","type":"link"}